Aeris F11 Operating Manual Download Page 29

29

F11 OPERATING MANUAL

© 2002 Design, 2013

Doc. No. 12-7285-r01 (5/3/13)

UPLOADING SETTINGS AND DOWNLOADING DATA

The F11 is configured with a Data Port located on the right side that enables it to be connected to a PC or Mac through a USB port 

using the AERIS Computer Interface cable, when viewing the Watch Main Time screen. 

The Settings Upload portion of the Computer Interface program can be used to set/change the Main Time/Date selections, Set 

Alarms, and Set Utilities. 

The Download portion of the program can be used to retrieve/copy data (Download it) from the F11 to the PC or Mac.  

The data includes items such as dive number, surface interval time, maximum depth, elapsed dive time, start date/time, start/end 

depth, lowest temperature underwater, sampling rate, dive profile, and set points. 

The F11 checks for the presence of an interface device connection to the Data Port once every second while operating in Watch 

Main Time mode.  Checks are not made if the Wet Activation contacts are wet. 

Upon sensing an interface connection with the PC or Mac, all segments of the LCD will be displayed.  This indicates that the PC or 

Mac and F11 are connected and prepared for upload of settings or download of data, which is then initiated using the Computer 

Interface program.

Operation reverts to the Watch Main Time screen after completion of the upload or download operation, or after 2 minutes if no PC 

or Mac action was taken.

Prior to attempting to download data from your F11 or upload settings to it, review the Help section of the Computer Interface 

program which serves as its user manual.  Recommended is to print those sections of Help that you consider appropriate for 

your interface activities.

PC requirements:

•  IBM

®

, or compatible, PC with USB Port

•  Intel

®

 Pentium 4 or better microprocessor

•  Microsoft

®

 Windows

®

  XP, Vista, 7, or 8

•  Super VGA card or compatible video graphics adaptor (256 color or greater) with a minimum 800 X 600 pixel screen area 

of display settings

•  128MB of available RAM

•  64MB of available hard drive storage

•  Mouse

•  CD Rom drive

•  Printer

Mac requirements:

•  Mac with USB Port

•  OSX 10.5 or later

•  Super VGA card or compatible video graphics adaptor (256 color or greater) with a minimum 800 X 600 pixel screen area 

of display settings

•  128MB of available RAM

•  64MB of available hard drive storage

•  Mouse

•  Printer

•  Internet connection to download App from the Apple App Store

For software updates, refer to the AERIS web site >>>>

www.diveaeris.com

For support, call ACI Support toll free at >>>>

(866) 732-7877, 8 Am to 5 Pm USA Pacific time.

Summary of Contents for F11

Page 1: ...1 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...

Page 2: ...t be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form without prior consent in writing from AERIS 2002 Design F11 Operating Manual Doc No 12 7285 2...

Page 3: ...full functions To wake the F11 up from Deep Sleep mode simultaneously depress the upper right S and lower left A buttons for 2 seconds until the display comes full ON displaying the MAIN TIME screen...

Page 4: ...4 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 Welcome to AERIS and THANK YOU for choosing the F11...

Page 5: ...5 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 GENERAL FEATURES DISPLAYS...

Page 6: ...r with the USB driver required is on the AERIS Product CD or it can be downloaded from the AERIS web site The program s Help serves as the user manual which can be printed for personal use The setting...

Page 7: ...full dive until entry into Surface mode when the Backlight operation reverts to normal POWER SUPPLY The F11 utilizes 1 3 volt CR2450 Lithium Battery Battery voltage is checked every 2 minutes during...

Page 8: ...8 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WATCH MODE...

Page 9: ...rm L 2 sec to toggle the Backlight On Off Will be On for the duration time set L 2 sec while the Backlight is On to reset the timer to keep it On for the full duration time set WATCH ALT Alternate inf...

Page 10: ...with Watch Main Time sound the Audible every day at the Time set while operating in Watch Mode not sound the Audible while operating in FREE Mode run in the background until set Off Daily Alarm Lead...

Page 11: ...F Hr and SEt with DUAL icon A hold to scroll upward through the set points 8 sec from 23 through 0 to 23 in increments of 1 hour A 2 sec to step upward through set points M 2 sec to step back through...

Page 12: ...atch Main M 2 sec to step back to Set Time Lead in M 2 sec or 2 minutes of no button action will revert to Watch Main Time L 2 sec to toggle the Backlight On Off Will be On for the duration time set L...

Page 13: ...13 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 surface mode...

Page 14: ...n sec with icons Surface Interval Time hr min_sec with SURF and sec icons Number of the last dive conducted that calendar day with DIVE icon If no dive has been made yet that day or if Dive is reset b...

Page 15: ...e Lead in screen If SET is selected the Set CDT screen is displayed S 2 sec to revert to CDT Lead in if no setting change M 2 sec or 2 minutes of no button action will revert to SURF MAIN L 2 sec to t...

Page 16: ...t On Off Will be On for the duration time set L 2 sec while the Backlight is On to reset the timer to keep it On for the full duration time set Set Alarms Lead in information includes Fig 27 Graphics...

Page 17: ...hing A 2 sec to step forward through the selections of OFF ON and SET M 2 sec to step back through the selections S 2 sec to step back to Set RTI Alarm S 2 sec to save the setting If OFF or ON is save...

Page 18: ...omatically upon entry into Dive Mode and remain On until the BDSI time up to 1 min elapses after surfacing L button operation of the Backlight will be disabled during the dive then enabled on the surf...

Page 19: ...and access Set Sampling Rate Set Sampling Rate information includes Fig 40 Graphic SAMP Time sec flashing with icon A 2 sec to step upward through set points of 0 25 0 50 1 00 2 00 sec one at a time...

Page 20: ...LOG HISTORY MODES A 2 sec while Watch Main Time or FREE SURF Main is displayed will access and step through Log and History modes Sequence Main Day Log Full Log Day History Full History Day and Full L...

Page 21: ...lude Fig 48 Log Mode book icon Graphic No and dive number 1 to 99 for that calendar day or session of the day if reset Max Depth with MAX and FT or M icons Elapsed Dive Time min sec with DIVE and min_...

Page 22: ...ay and the Dive Time displayed is associated with that Max Depth Max Depth achieved that day with MAX and FT or M icons Dive Time min sec for that dive with DIVE and min_sec icons A 2 sec to access Da...

Page 23: ...n is to include Fig 59 Graphic LONG indicating that the information displayed is for the longest Dive Time ever recorded and the Max Depth dis played is associated with that Dive Time Max Depth with M...

Page 24: ...ivated upon descent to the DSD Dive Start Depth set for 1 second then the dive ends upon ascent above 2 FT 0 6 M for 1 second If a descent is made while the Chrono is on the display it will remain on...

Page 25: ...s ALT S 2 sec to start stop the CDT If set for Auto the countdown will repeat each time it counts down to 0 00 S 2 sec to reset the CDT to the time min sec set M 2 sec to replace the Dive Main with Ch...

Page 26: ...26 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WARNINGS ALARMS...

Page 27: ...ing which the graphic SRT will flash on the Surface Main screen in place of the graphic FREE or the CDT if set for use LOW BATTERY ALARM while in FREE Mode Fig 72 73 When a Low Battery warning condit...

Page 28: ...28 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 REFERENCE...

Page 29: ...upload of settings or download of data which is then initiated using the Computer Interface program Operation reverts to the Watch Main Time screen after completion of the upload or download operation...

Page 30: ...Additional information is available at the AERIS web site diveaeris com battery replacement CAUTION The procedures that follow must be closely adhered to avoid entrance of water into the unit Damage...

Page 31: ...as a guide for top bottom Also small symbols have been engraved on the top of the cover and strap to serve as a guide for proper alignment Fig 85a While ensuring that the cover and back of the case ar...

Page 32: ...33 M OFF 100 FT 33 M DA1 to DA6 OFF ON SET 10 to 495 FT 3 to 150 M All OFF 330 FT 100 M DA1 to DA6 Audible 1 to 10 beeps 1 to 3 times All OFF 3 beeps 3 times Set Utilities Factory Settings Units Impe...

Page 33: ...with the Backlight on full time during dives 1 year using as a Watch only Battery Indicator Warning icon on solid 2 75 volts 2 50 volts Battery change recommended Alarm icon on flashing at 2 50 volts...

Page 34: ...rmation Transducer An electro mechanical device in a dive gauge that acts as a depth sensor WARNINGS Conducting Free dives within a 24 hour period after conducting SCUBA dives combined with the effect...

Page 35: ...___________________________________________________________________________________________________ Purchased from ____________________________________________________________________________________...

Page 36: ...36 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...

Reviews: