SURFACE SET MODES
To access:
SURF MAIN >> ALT 1 >> ALT 2 >> CDT >> SET ALARMS >> SET UTILITIES.
• A (< 2 sec) to access and step through the sequence.
> Set points can also be changed using the AERIS Computer Interface program.
> Settings remain at the values saved until changed.
SET ALARMS
Sequence: Lead-in >> AUD >> SRT >> RTI >> RDI >> DA1 to DA6.
• A (< 2 sec), while viewing CDT Lead-in, to access Set Alarms Lead-in.
The Set Audible feature provides complete OFF control of the Audible and its associated LED warning light. When set OFF, no
beeps will be emitted and the light will not flash when an alarm condition occurs, which some divers prefer during select activities.
Icons and messages will still flash and the Backlight will still come On.
The SRT (Surface Recovery Time) Alarm provides an alert when a set 'recovery time' has elapsed after surfacing from a dive.
The RTI (Repeating Time Interval) Alarm repeats each time the Time Interval set is reached during operation in Dive Mode.
The RDI (Repeating Depth Interval) Alarm repeats each time the Depth Interval set is reached, except when the DA alarms strike. If a
series of descents, ascents, descents is made, the alarm will activate during each of the Descents.
The DA 1 to DA6 (Descending/Ascending) Depth Alarms are set and operate with no restrictions (such as sequence) while ascend-
ing as well as descending. Unless set Off, the audible sounds for the number of beeps set for that depth each time you reach (pass
through) the Depth set while descending and/or ascending.
At any time while entering settings -
• M (2 sec), or 2 minutes of no button action, will revert to SURF MAIN.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
Set Alarms Lead-in,
information includes (Fig. 27):
> Graphics Go To SEt - A.
• S (< 2 sec) - to access Set Audible.
• A (< 2 sec) - to step forward to Set Utilities Lead-in.
• M (< 2 sec) - to step back to CDT Lead-in.
Set Audible Alarm,
information includes (Fig. 28):
> Graphic AUD.
> Graphic ON (or OFF), flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (2 sec) - to step back to Set Alarms Lead-in.
• S (< 2 sec) - to save the setting and access Set SRT Alarm.
Set SRT (Surface Recovery Time) Alarm,
information includes (Fig. 29):
> Graphic SRT with min_sec icons.
> Time (min:sec).
> Graphic ON (or OFF), flashing.
• A (< 2 sec) - to step forward through the selections of OFF, ON, and SET.
• M (< 2 sec) - to step back through the selections.
• S (2 sec) - to step back to Set Audible.
• S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set RTI Alarm.
> If SET is saved, the Minute digits will flash.
• A (hold) - to scroll upward through the Minute set points at a rate of 8 per second from 0: to 30: in increments of 1 minute.
• A (< 2 sec) - to step upward through the Minute set points one at a time.
• M (< 2 sec) - to step back through the Minute set points one at a time.
• S (2 sec) - to step back to SEt flashing.
• S (< 2 sec) - to save the Minute setting and flash the Seconds digits.
• A (hold) - to scroll upward through the Second set points at a rate of 8 per second from :00* to :59 in increments of 1 second.
*Starts at :01 (sec) minimum when Minutes are set for 0: (min).
• A (< 2 sec) - to step upward through the Second set points one at a time.
• M (< 2 sec) - to step back through the Second set points one at a time.
• S (2 sec) - to step back to the Minutes digits flashing.
• S (< 2 sec) - to save the min:sec setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Fig. 27 - SET ALARMS
LEAD-IN
Fig. 28 - SET AUDIBLE
ALARM
Fig. 29 - SET SRT ALARM
Summary of Contents for F11
Page 1: ...1 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...
Page 5: ...5 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 GENERAL FEATURES DISPLAYS...
Page 8: ...8 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WATCH MODE...
Page 13: ...13 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 surface mode...
Page 26: ...26 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WARNINGS ALARMS...
Page 28: ...28 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 REFERENCE...
Page 36: ...36 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...