![Aeris F11 Operating Manual Download Page 19](http://html1.mh-extra.com/html/aeris/f11/f11_operating-manual_2861745019.webp)
19
F11 OPERATING MANUAL
© 2002 Design, 2013
Doc. No. 12-7285-r01 (5/3/13)
Set Wet Activation,
information includes (Fig. 36):
> Graphics WET ACt.
> Graphic ON (or OFF), flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (2 sec) - to step back to Set Units.
• S (< 2 sec) - to save the setting and access Set Water Type.
Set Water Type,
information includes (Fig. 37):
> Graphics H2O tYPE.
> Graphic SEA (or FrSH), flashing.
• A or M (< 2 sec) - to toggle between SEA and FrSH.
• S (2 sec) - to step back to Set Wet Activation.
• S (< 2 sec) - to save the setting and access Set Backlight Duration.
Set backlight Duration,
information includes (Fig. 38):
> Graphics GLO and durA.
> Time (min:sec) flashing, with icons.
• A (< 2 sec) to step upward through set points of 0:05, 0:10, 0:30, 1:00 (min:sec) one at a time.
• M (< 2 sec) to step back through the set points one at a time.
• S (2 sec) - to step back to Set Water Type.
• S (< 2 sec) to save the setting and access Set Auto Glo.
Set Auto Glo,
information includes (Fig. 39):
> Graphics AUTO GLO with DIVE icon.
> Graphic ON (or OFF), flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (2 sec) - to step back to Set Backlight Duration.
• S (< 2 sec) - to save the setting and access Set Sampling Rate.
Set Sampling Rate,
information includes (Fig. 40):
> Graphic SAMP.
> Time (sec), flashing, with icon.
• A (< 2 sec) to step upward through set points of 0.25, 0.50, 1.00, 2.00 (sec) one at a time.
• M (< 2 sec) to step back through the set points one at a time.
• S (2 sec) - to step back to Set Auto Glo.
• S (< 2 sec) to save the setting and access Set DSD.
Set DSD (Dive Start Depth),
information includes (Fig. 41):
> Graphic DSD.
> Depth flashing, with FT (or M) icon.
• A (< 2 sec) to step upward through the set points of 2, 4, 6 FT (0.6, 1.2, 1.8 M) one at a time.
• M (< 2 sec) to step back through set points one at a time.
• S (2 sec) - to step back to Set Sampling Rate.
• S (< 2 sec) to save the setting and access Set BDSI.
Set bDSI (between Dive Surface Interval),
information includes (Fig. 42):
> Graphic BDSI with min & sec icons.
> Time (min:sec) flashing, with SURF icon.
• A (hold) to scroll upward through the set points 8 per second from 0:01 to 1:00 (min:sec) in increments of :01 (1 sec).
• A (< 2 sec) to step upward through the set points one at a time.
• M (< 2 sec) to step back through the set points one at a time.
• S (2 sec) - to step back to Set DSD.
• S (< 2 sec) to save the setting and revert to Set Utilities Lead-in.
------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------
Fig. 38 - SET BACKLIGHT
DURATION
Fig. 42 - SET BDSI
Fig. 37 - SET WATER
TYPE
Fig. 41 - SET DSD
Fig. 39 - SET AUTO GLO
Fig. 40 - SET SAMPLING
RATE
Fig. 36 - SET WET
ACTIVATION
Summary of Contents for F11
Page 1: ...1 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...
Page 5: ...5 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 GENERAL FEATURES DISPLAYS...
Page 8: ...8 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WATCH MODE...
Page 13: ...13 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 surface mode...
Page 26: ...26 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 WARNINGS ALARMS...
Page 28: ...28 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 REFERENCE...
Page 36: ...36 F11 OPERATING MANUAL 2002 Design 2013 Doc No 12 7285 r01 5 3 13 F11 OPERATING MANUAL...