background image

AerAtron >> Silent Efficiency 

 

 

IF

 

THERE

 

ARE

 

ANY

 

PROBLEMS

 

DURING

 

INSTALLATION

 

OF

 

THE

 

FAN,

 

THE

 

INSTALLER

 

MUST

 

CONTACT

 

THE

 

AERATRON

 

HELP

 

LINE

 

BEFORE

 

LEAVING

 

THE

 

SITE:

 

SWISS

 

PRECISION

 

+61

 

410

 

465

 

228

 

 

Installation - Operation – Maintenance - Warranty

 

4

Ensure

 

ceiling

 

joists

 

are

 

sound

 

and

 

of

 

adequate

 

size

 

and

 

strength

 

to

 

support

 

a

 

35Kg

 

(77lb)

 

load.

 

 

To

 

reduce

 

the

 

risk

 

of

 

fire,

 

electrical

 

shock

 

or

 

personal

 

injury,

 

ensure

 

that

 

the

 

fan

 

mounting

  

bracket

 

is

 

supported

 

directly

 

from

 

the

 

building

 

structure.

 

DO

 

NOT

 

mount

 

to

 

an

 

outlet

 

box.

 

 

The

 

mounting

 

bracket

 

must

 

be

 

firmly

 

screwed

 

to

 

a

 

load

 

bearing

 

structure

 

e.g.

 

a

 

concrete

 

ceiling,

 

steel

 

structure

 

or

 

timber

 

frame.

 

If

 

a

 

timber

 

frame

 

is

 

to

 

be

 

added

 

it

 

must

 

be

 

securely

 

nailed

 

or

 

screwed

 

between

 

two

 

beams.

 

 

Mechanical

 

issues

 

Do

 

not

 

remove

 

the

 

fan

 

from

 

the

 

ceiling

 

after

 

installation.

 

 

Do

 

not

 

attach

 

the

 

Fan

 

Assembly

 

before

 

the

 

Fan

 

Motor

 

Housing

 

is

 

installed

 

and

 

secured.

  

To

 

protect

 

the

 

finish,

 

the

 

Fan

 

Motor

 

Housing

 

should

 

be

 

kept

 

in

 

the

 

carton

 

until

 

ready

 

to

 

be

 

installed.

 

 

After

 

the

 

fan

 

is

 

completely

 

installed,

 

check

 

to

 

make

 

sure

 

that

 

all

 

connections

 

are

 

secure

 

to

 

prevent

 

the

 

fan

 

from

 

falling

 

and/or

 

causing

 

damage

 

or

 

injury.

 

 

To

 

reduce

 

the

 

risk

 

of

 

personal

 

injury,

 

do

 

not

 

bend

 

or

 

damage

 

the

 

motor

 

Drive

 

Shaft

 

or

 

Fan

 

Assembly

 

when

 

handling

 

or

 

installing

 

 

Aeratron

 

fans

 

are

 

equipped

 

with

 

a

 

self

balancing

 

system

 

and

 

do

 

not

 

require

 

manual

 

balancing!

 

 
 

Electrical

 

issues

 

 

!

 

Means

 

for

 

disconnection

 

must

 

be

 

incorporated

 

in

 

the

 

fixed

 

wiring

 

in

 

accordance

 

with

 

national

 

wiring

 

rules!

  

 

The

 

fan

 

can

 

be

 

used

 

in

 

conjunction

 

with

 

some

 

home

 

automation

 

systems.

 

For

 

further

 

information

 

please

 

contact

  

Aeratron

 

Pty

 

Ltd.

 

 

To

 

avoid

 

possible

 

electric

 

shock

 

during

 

installation,

 

be

 

sure

 

electricity

 

is

 

turned

 

off

 

at

 

the

 

main

 

power

 

box

 

before

 

commencing

 

work.

 

Disconnect

 

power

 

by

 

removing

 

fuse

 

or

 

turning

 

off

 

circuit

 

breaker

 

before

 

installing

 

the

 

fan.

 

Ensure

 

all

 

spliced

 

connections

 

are

 

adequately

 

insulated.

 

 

Note:

 

Nothing

 

in

 

this

 

manual

 

is

 

intended

 

to

 

instruct

 

or

 

assist

 

untrained

 

or

 

unqualified

 

persons

 

to

 

install

 

this

 

product.

 

Additionally,

 

it

 

is

 

the

 

responsibility

 

of

 

the

 

installer

 

and

 

user

 

to

 

apply

 

common

 

sense

 

and

 

care

 

at

 

all

 

times.

 

Summary of Contents for E502

Page 1: ...AerAtron Ceiling fans User Manual Technical Specifications Models e502 e503 Australian edition 2011 ...

Page 2: ... Attaching Fan Motor Housing to Motor Assembly 9 Closing Screw Cover 9 Fan Blades and Middle Piece Assembly 10 e502 10 e503 11 Fan Blades to Shaft Assembly 12 Remote Control Set up 13 Code match your transmitter and receiver 13 Code match for Transmitter Hand held and Receiver 13 Technical specifications 14 e503 and e502 14 Sloped Ceiling 15 Care Cleaning 16 If the fan is noisy 16 If the fan rotat...

Page 3: ...sembly diagrams before installing your new fan This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with ...

Page 4: ...ton until ready to be installed After the fan is completely installed check to make sure that all connections are secure to prevent the fan from falling and or causing damage or injury To reduce the risk of personal injury do not bend or damage the motor Drive Shaft or Fan Assembly when handling or installing Aeratron fans are equipped with a self balancing system and do not require manual balanci...

Page 5: ...on Maintenance Warranty 5 Unpacking your fan Unpack your fan and check the contents Do not discard the carton If warranty replacement or repair is ever necessary the fan should be returned in the original packaging Examine all parts You should have the following Hanger Bracket Motor Assembly Motor Housing Hanger Bracket Fastener Remote Control Receiver Remote Control Transmitter 9V Battery OR HUB ...

Page 6: ... turning off circuit breaker before commencing work Installation mounted to Ceiling Joist Install mounting bracket to ceiling joist using the screws and washer provided The mounting plate should be able to hold a weight of at least 18kgs NOTE Proper care must be taken when mounting to concrete ceilings For safe mounting these ceilings may require plastic plugs anchors and stronger screws Preparing...

Page 7: ...nstallation Operation Maintenance Warranty 7 NOTE Installation of multiple fans using independent transmitter require CODE MATCH before installing the receiver see page 13 Installing Remote Control Receiver into hanger bracket Slide Remote Control Receiver After installing receiver re into Hanger Brackets in orientation adjust Fan Motor assembly shown to ensure the drive shaft is vertical ...

Page 8: ...tion Operation Maintenance Warranty 8 Make LIVE GROUND and NEUTRAL connections from Mains Power House to Terminal Block Make LIVE GROUND and NEUTRAL connections from Remote Control Receiver to Terminal Block Plug the 9 Pole plug connector from the DC Motor into the 9 Pole plug connector from the Receiver Preparing Fan Motor Housing Ensure that Motor Housing Screw Covers are in full open position ...

Page 9: ...ration Maintenance Warranty 9 Attaching Fan Motor Housing to Motor Assembly Line up fixing hole Install motor housing in Motor Housing with using a clockwise screw hole in chassis Bayonet action and install screw Ensure that Fan Motor Housing fixing point with hole not bayonet slot is aligned with chassis arm from which fixing screw was removed see page 6 Closing Screw Cover Close all three Screw ...

Page 10: ...ece Assembly CONSTANTLY HANDLE FAN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN SURFACE e502 Place e502 Hub Upper onto a clean working area Line up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper Fix the e500 Fan Blade tight and firm using 2 Hub screws Fix second e500 Blade tight and firm using 2 Hub screws With care turn the fan over and fasten...

Page 11: ...AN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN SURFACE e503 Place e503 Hub Upper onto a clean working area Line up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper Fix the e500 Fan Blade tight and firm using 2 Hub screws Fix second and third e500 Blades tight and firm using 2 Hub screws for each Blade With care turn the fan over and fasten the e...

Page 12: ...ONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE SWISS PRECISION 61 410 465 228 Installation Operation Maintenance Warranty 12 Fan Blades to Shaft Assembly Rotate Screw Cover to hide screw head Note Rotating the Screw Cover will prevent Pivot screw from falling out should it become loose Pivot Screw ...

Page 13: ...upport heating system to exchange temperature Code match for Transmitter Hand held and Receiver 1 Set the code to be encoded by the Dip Switch of transmitter 2 Switch on the main power to activate the receiver 3 Within 3 minutes after the power is turned on press the transmitter s ON OFF key and do not release for 5 seconds 4 Receiver issues four beep short sounds which indicates successful code m...

Page 14: ...ty 14 Technical specifications e503 and e502 Colour white silver black Remote control Hand Held RF Dimensions e502 as e503 Operating speed rpm Power Usage Watt e503 Speed 1 51 rpm 3 8 W Speed 2 70 rpm 4 5 W Speed 3 103 rpm 7 5 W Speed 4 119 rpm 9 5 W Speed 5 139 rpm 13 6 W Speed 6 158 rpm 18 W e502 Speed 1 52 rpm 3 9 W Speed 2 73 rpm 4 5 W Speed 3 113 rpm 7 7 W Speed 4 131 rpm 9 6 W Speed 5 153 rp...

Page 15: ...cy IF THERE ARE ANY PROBLEMS DURING INSTALLATION OF THE FAN THE INSTALLER MUST CONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE SWISS PRECISION 61 410 465 228 Installation Operation Maintenance Warranty 15 Sloped Ceiling ...

Page 16: ...on below WARNING Except for items 1 and 2 below the following require access to areas of the fan which carry lethal voltage There are no other checks which can be carried out by the user Apart from items 1 and 2 the following must be carried out by properly qualified personnel If the fan does not operate properly or turns on or off at random 1 If applicable change the battery in the Remote Control...

Page 17: ...ts even slightly damaged or bent during vigorous cleaning or bumping can cause wobble and noise This is not covered under warranty but care during maintenance and cleaning should prevent this from occurring Ceiling Fan Warranty You must have the original purchase receipt or bill of sale to make a warranty claim No claim will be accepted unless proof of date of purchase is available at the time of ...

Page 18: ...y a licensed electrician 3 Repair of a ceiling fan used incorrectly accidentally damaged modified in any way or not serviced in accordance with the maintenance instructions 4 Travelling costs incurred by Aeratron Pty Ltd personnel or service agents and or the cost of transporting and insuring the ceiling fan between the nearest Aeratron Pty Ltd agents service depot and its normal location These co...

Page 19: ...tron ceiling fan warranty details Please File with your Purchase Receipt Customer Details Name ______________________________________________ Address ____________________________________________ Post Code ___________________________________________ Phone Number _______________________________________ Fan Details Model ______________________________________________ Colour __________________________...

Page 20: ... PROBLEMS DURING INSTALLATION OF THE FAN THE INSTALLER MUST CONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE SWISS PRECISION 61 410 465 228 Installation Operation Maintenance Warranty 20 Thank you Your AerAtron team Australian edition 2011 ...

Reviews: