background image

COMMAND_CLASS_VERSION (V2) 

COMMAND_CLASS_POWERLEVEL (V1) 

COMMAND_CLASS_ASSOCIATION (V2) 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3) 

COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1) 

COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2) 

COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1) 

COMMAND_CLASS_BATTERY (V1) 

COMMAND_CLASS_WAKEUP (V2) 

COMMAND_CLASS_NOTIFICATION (V8) 

COMMAND_CLASS_SENSOR_BINARY (V2) 

COMMAND_CLASS_SENSOR_MULTILEVEL (V7) 

COMMAND_CLASS_CONFIGURATION (V1) 

COMMAND_CLASS_SUPERVISION (V1) 

 
The full text of the declaration is available from https://support.aeotec.com/trisensor/doc 
 

Specifications.

Z-Wave devices operate between 868.40 & 926.30 MHz depending on local 

restrictions. It uses up to -0.36dBm ERP transmit power, enabling long range connectivity. Full 
information on device specifications and certifications at support.aeotec.com/trisensor/specs 

California Proposition 65. 

WARNING: This product contains a chemical known to the State of 

California to cause birth defects or other reproductive harm. Use only for intended purposes. Do 
not use for other purposes including, but not limited to, the consumption of food and drinks. 
 
 
 
 

 

 
 

Summary of Contents for ZWA005

Page 1: ...oth Tips on optimising the installation location of TriSensor can be found online in its digital guide 2 Remove the backplate from TriSensor 3 Insert one CR123A batteries with the correct orientation...

Page 2: ...blem with TriSensor visit http support aeotec com trisensor or contact our support team via aeotec com contact You can also learn more about TriSensor features configuration options and technical spec...

Page 3: ...sensitivity that motion detect 0 PIR sensor disabled 1 Lowest sensitivity 11 Highest sensitivity Parameter Number Size Byte Available Settings Default value 3 1 0 11 11 4 Binary Sensor Report Enable...

Page 4: ...m Value This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is larger than this configuration value device will send a BASIC_SE...

Page 5: ...ight Sensor Report 0 Disable 1 Red 2 Green 3 Blue 4 Yellow 5 Pink 6 Cyan 7 Purple 8 Orange Parameter Number Size Byte Available Settings Default value 13 1 0 8 0 12 Led Color For Battery Report 0 Disa...

Page 6: ...or F Parameter Number Size Byte Available Settings Default value 21 2 0 250 20 16 Light intensity Threshold Value to Report Change threshold value for change in light sensor to induce an automatic rep...

Page 7: ...this parameter setting User should run the steps as blows for calibrating 1 Set this parameter value to default Assumes the sensor has been added in a Z Wave Network 2 Place a digital luxmeter close t...

Page 8: ...ON V1 The full text of the declaration is available from https support aeotec com trisensor doc Specifications Z Wave devices operate between 868 40 926 30 MHz depending on local restrictions It uses...

Reviews: