6)

 

Basic Set Value Settings for Group 2  
‘0’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is 

triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is 
cleared. 

‘1’– Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is 

triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is 
cleared. 

‘2’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is 

triggered. 

‘3’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is 

triggered. 

‘4’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is 
cleared. ‘5’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event 
is cleared. 

Parameter Number  Size (Byte) 

Available Settings 

Default value 

0 ~ 5 

  

7)

 

Temperature Alarm Value  
This parameter is configured the threshold value that alarm level for temperature. When the 

current  ambient  temperature  value  is  larger  than  this  configuration  value,  device  will  send  a 
BASIC_SET  =  0xFF  to nodes associated in group 3. If current temperature value is  less than 
this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3. 

Value = [Value] × 0.1(Celsius / Fahrenheit)  

Parameter Number  Size (Byte) 

Available Settings 

Default value 

EU/AU  2 

-400~850 (Celsius) 

239 (Celsius) 

US 

-400~1185 (Fahrenheit) 

750 (Fahrenheit) 

  

8)

 

Led Indicate Disable  
This parameter is configured the Led light on disable or enable. 

‘1’ – Enable Led Blink when device detects a motion event. 
‘0’ – Disable Led Blink. This configuration is not affect inclusion, exclusion and reset. 

Parameter Number  Size (Byte) 

Available Settings 

Default value 

10 

0, 1 

  

9)

 

Led Color For Motion Event  Report  
‘0’ – Disable.  
‘1’ – Red. 
‘2’ – Green. 
‘3’ – Blue. 
‘4’ – Yellow. 
‘5’ – Pink. 
‘6’ – Cyan. 
‘7’ – Purple. 
‘8’ – Orange.  

Parameter Number  Size (Byte) 

Available Settings 

Default value 

11 

0 ~ 8 

Summary of Contents for ZWA005

Page 1: ...oth Tips on optimising the installation location of TriSensor can be found online in its digital guide 2 Remove the backplate from TriSensor 3 Insert one CR123A batteries with the correct orientation...

Page 2: ...blem with TriSensor visit http support aeotec com trisensor or contact our support team via aeotec com contact You can also learn more about TriSensor features configuration options and technical spec...

Page 3: ...sensitivity that motion detect 0 PIR sensor disabled 1 Lowest sensitivity 11 Highest sensitivity Parameter Number Size Byte Available Settings Default value 3 1 0 11 11 4 Binary Sensor Report Enable...

Page 4: ...m Value This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is larger than this configuration value device will send a BASIC_SE...

Page 5: ...ight Sensor Report 0 Disable 1 Red 2 Green 3 Blue 4 Yellow 5 Pink 6 Cyan 7 Purple 8 Orange Parameter Number Size Byte Available Settings Default value 13 1 0 8 0 12 Led Color For Battery Report 0 Disa...

Page 6: ...or F Parameter Number Size Byte Available Settings Default value 21 2 0 250 20 16 Light intensity Threshold Value to Report Change threshold value for change in light sensor to induce an automatic rep...

Page 7: ...this parameter setting User should run the steps as blows for calibrating 1 Set this parameter value to default Assumes the sensor has been added in a Z Wave Network 2 Place a digital luxmeter close t...

Page 8: ...ON V1 The full text of the declaration is available from https support aeotec com trisensor doc Specifications Z Wave devices operate between 868 40 926 30 MHz depending on local restrictions It uses...

Reviews: