Aeotec ZWA005 Manual Download Page 2

green  and then LED will pulse a blue.If  fail, the yellow LED lasts for 30 seconds, then the 
greenLED flashes once. 

 

           figure1

 

8.  TriSensor can be installed on a flat surface such as a shelf, in a corner or on a wall using the 

Back-Mount Arm, or within a ceiling or wall using its Recessor accessory (sold separately). If 
using the Back-Mount Arm; 

a.  Screw Back-Mount Arm into the corresponding threaded hole on the back of TriSensor. 
b.  Affix Back-Mount Arm to your desired location using the provided double-sided tape or 

KA2.5×20 mm screws. 

c.  Angle the TriSensor as desired. 

 

Get help & learn more.

 

Should you encounter any problem with TriSensor, visit http://support.aeotec.com/trisensor or contact 
our support team via aeotec.com/contact. You can also learn more about TriSensor features, 
configuration options, and technical specifications at the link. 
 

Gateway compatibility.

 


To see if this device is known to be compatible with your Z-Wave gateway, please refer to 
http://aeotec.com/z-wave-gateways  

 

 

Declaration of Conformity. 

Aeotec Limited declares that TriSensor is in compliance with the essential requirements and other 
relevant provisions of RED 2014/53/EU, RoHS 2011/65/EU, IEC62321:2008 and EN50581:2012. 

 

Command Class Configuration  

 

The device supports the controller to configure parameters of the device through Configuration 
Command Class, and the device has 21 parameters available for users to set according to their 
different needs: 

Summary of Contents for ZWA005

Page 1: ...oth Tips on optimising the installation location of TriSensor can be found online in its digital guide 2 Remove the backplate from TriSensor 3 Insert one CR123A batteries with the correct orientation...

Page 2: ...blem with TriSensor visit http support aeotec com trisensor or contact our support team via aeotec com contact You can also learn more about TriSensor features configuration options and technical spec...

Page 3: ...sensitivity that motion detect 0 PIR sensor disabled 1 Lowest sensitivity 11 Highest sensitivity Parameter Number Size Byte Available Settings Default value 3 1 0 11 11 4 Binary Sensor Report Enable...

Page 4: ...m Value This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is larger than this configuration value device will send a BASIC_SE...

Page 5: ...ight Sensor Report 0 Disable 1 Red 2 Green 3 Blue 4 Yellow 5 Pink 6 Cyan 7 Purple 8 Orange Parameter Number Size Byte Available Settings Default value 13 1 0 8 0 12 Led Color For Battery Report 0 Disa...

Page 6: ...or F Parameter Number Size Byte Available Settings Default value 21 2 0 250 20 16 Light intensity Threshold Value to Report Change threshold value for change in light sensor to induce an automatic rep...

Page 7: ...this parameter setting User should run the steps as blows for calibrating 1 Set this parameter value to default Assumes the sensor has been added in a Z Wave Network 2 Place a digital luxmeter close t...

Page 8: ...ON V1 The full text of the declaration is available from https support aeotec com trisensor doc Specifications Z Wave devices operate between 868 40 926 30 MHz depending on local restrictions It uses...