Aeotec Water Sensor 7 Pro User Manual Download Page 9

17/06/2021

Water Sensor 7 Pro user guide (ZWA019/ZWA044) : Aeotec Help Desk

https://help.aeotec.com/support/solutions/articles/6000235950-water-sensor-7-pro-user-guide-zwa019-zwa044-

9/9

This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity
changes. However, periodic
reports, managed by configuration parameter 18, may still be active.
0 - disabled
1-20 - value in %

18. Periodic Reports.

Parameter: 18
Size: 2 Byte
Default Value: 43200
Description:

This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no
periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by
configuration parameters 16 and 17, may still be active.
0 - disabled
900-65535 - value in seconds

64. Temperature Scale

Parameter: 64
Size: 1 Byte
Default Value: 1
Description:

This parameter sets the temperature scale.
1 - Celsius
2 - Fahrenheit

255. Reset Parameter 
Parameter: 255

Size: 4 Byte
Default Value: 0
Description:

This parameter helps reset configuration parameters and the device to factory defaults
1- Reset all Parameter settings to their default settings.
1431655765 - (0x55555555) Completely factory reset sensor and send device reset locally notification

Summary of Contents for Water Sensor 7 Pro

Page 1: ...wave home automation z wave gen7 html technology and S2 framework You can find out more about Water Sensor 7 https aeotec com z wave door window sensor by following that link To see whether Water Sens...

Page 2: ...held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials Keep product and batteries away from open flames and extreme heat Avoid direct...

Page 3: ...h it When the probe contacts come into contact with a liquid the Water Sensor 7 sends a leak warning to your Z Wave Gateway Make sure that both contacts are capable of detecting leaks or flooding Addi...

Page 4: ...r 18 or by the change in value Parameter 16 Multilevel Sensor Report Humidity This sensor will report occasionally on its own as an unsolicited Multilevel Sensor Report either by a timed interval Para...

Page 5: ...ce See Learn Mode AdvancedFunctions Communication test This utilizes the Power Level command class to determine the health between the Water Sensor 7 and your Z Wave gateway This will tell you if the...

Page 6: ...activate Reset your Water Sensor 7 This device also allows being reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inoperable To ma...

Page 7: ...tamper switch 0 disabled 1 enabled 5 2nd Association Group Trigger Parameter 5 Size 1 Byte Default Value 0 Description This parameter defines the status of the water leakage that causes sending a BASI...

Page 8: ...tion Parameter 11 Size 2 Byte Default Value 0 Description Time a tamper alarm is delayed 0 32400 Seconds 12 Reporting tamper alarm cancellation Parameter 12 Size 1 Byte Default Value 1 Description Thi...

Page 9: ...e 43200 Description This parameter defines the time interval to send an unsolicited report If the value is set to 0 there will be no periodic reports sent to the controller However reports on temperat...

Reviews: