3. Visual LED indications

Parameter: 3
Size: 1 Byte
Default Value: 7 

Description: 

This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
(values 1 + 2 + 4 summarized)
0 - No indications
1 - Water Leakage Status Change
2 - Wake Up (1 x click)
4 - Device tampering

4. Range test after double click

Parameter: 4
Size: 1 Byte
Default Value: 0 
Description:

 

Allows enabling the activation of a Z-Wave range test with double-clicking the tamper switch.
0 - disabled
1 - enabled

5. 2nd Association Group Trigger

Parameter: 5
Size: 1 Byte
Default Value: 0 
Description:

 

This parameter defines the status of the water leakage that causes sending a BASIC command to all devices of
Association Group 2.
0 - Switch after Water Leakage Start and Stop
1 - Switch after Water Leakage Start
2 - Switch after Water Leakage Stop

6. Command Sent to Devices of Association Group 2

Parameter: 6
Size: 1 Byte
Default Value: 255
Description:

 

This parameter defines which commands are sent to 2nd Association Group
0 - On
1 - Off
2 - On and Off

7. BASIC command value sent to 2nd Association Group on On event

Parameter: 7
Size: 1 Byte
Default Value: 255 
Description: 

This is the BASIC command value sent in case of On even
0 - 99 -  Value
255 - On 

8. BASIC command value sent to 2nd Association Group on Off event

Parameter: 8
Size: 1 Byte

Summary of Contents for Water Sensor 7 Pro

Page 1: ...wave home automation z wave gen7 html technology and S2 framework You can find out more about Water Sensor 7 https aeotec com z wave door window sensor by following that link To see whether Water Sens...

Page 2: ...held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials Keep product and batteries away from open flames and extreme heat Avoid direct...

Page 3: ...h it When the probe contacts come into contact with a liquid the Water Sensor 7 sends a leak warning to your Z Wave Gateway Make sure that both contacts are capable of detecting leaks or flooding Addi...

Page 4: ...r 18 or by the change in value Parameter 16 Multilevel Sensor Report Humidity This sensor will report occasionally on its own as an unsolicited Multilevel Sensor Report either by a timed interval Para...

Page 5: ...ce See Learn Mode AdvancedFunctions Communication test This utilizes the Power Level command class to determine the health between the Water Sensor 7 and your Z Wave gateway This will tell you if the...

Page 6: ...activate Reset your Water Sensor 7 This device also allows being reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inoperable To ma...

Page 7: ...tamper switch 0 disabled 1 enabled 5 2nd Association Group Trigger Parameter 5 Size 1 Byte Default Value 0 Description This parameter defines the status of the water leakage that causes sending a BASI...

Page 8: ...tion Parameter 11 Size 2 Byte Default Value 0 Description Time a tamper alarm is delayed 0 32400 Seconds 12 Reporting tamper alarm cancellation Parameter 12 Size 1 Byte Default Value 1 Description Thi...

Page 9: ...e 43200 Description This parameter defines the time interval to send an unsolicited report If the value is set to 0 there will be no periodic reports sent to the controller However reports on temperat...

Reviews: