Aeotec Water Sensor 7 Pro User Manual Download Page 6

17/06/2021

Water Sensor 7 Pro user guide (ZWA019/ZWA044) : Aeotec Help Desk

https://help.aeotec.com/support/solutions/articles/6000235950-water-sensor-7-pro-user-guide-zwa019-zwa044-

6/9

Note: Water Sensor 7 remains awake until the housing is closed again.

Remove your Water Sensor 7 from Z-Wave network.

Your sensor can be removed from your Z-Wave network at any time. You'll need to use your Z-Wave network's main
controller/gateway. To do this, please refer to the part of your gateways respective manual that tells you how to remove
devices from your network. 

1. Set your Z-Wave controller into unpair mode.
2. Triple-click the tamper switch on Water Sensor 7 within 1.5 seconds - this will cause the LED to blink five times.
3. After a successful exclusion, it will light up its LED for 2 seconds then deactivate.

Reset your Water Sensor 7.

This device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used
when the primary controller is inoperable. 

To manually factory reset:

1. Remove the cover of Water Sensor 7
2. Press and hold tamper switch for 5 seconds until the red LED blinks.
3. Release the tamper switch
4. Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.

Association Groups

Group Association allows Water Sensor to directly communicate with other Z-Wave devices directly without the need for
the Z-Wave Controller to act as an in-between controller. This using this function will help with communication efficiency
and limit the amount of time it takes to control a device.

Group
Number

Maximum
Nodes

Description

1

5

Lifeline

2

5

Control devices when water leakage is detected 

 

3

5

Sends out alarm message when water leakage is
detected

 

4

5

Sends alarm messages when tamper is tripped

Parameter setting.

Summary of Contents for Water Sensor 7 Pro

Page 1: ...wave home automation z wave gen7 html technology and S2 framework You can find out more about Water Sensor 7 https aeotec com z wave door window sensor by following that link To see whether Water Sens...

Page 2: ...held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials Keep product and batteries away from open flames and extreme heat Avoid direct...

Page 3: ...h it When the probe contacts come into contact with a liquid the Water Sensor 7 sends a leak warning to your Z Wave Gateway Make sure that both contacts are capable of detecting leaks or flooding Addi...

Page 4: ...r 18 or by the change in value Parameter 16 Multilevel Sensor Report Humidity This sensor will report occasionally on its own as an unsolicited Multilevel Sensor Report either by a timed interval Para...

Page 5: ...ce See Learn Mode AdvancedFunctions Communication test This utilizes the Power Level command class to determine the health between the Water Sensor 7 and your Z Wave gateway This will tell you if the...

Page 6: ...activate Reset your Water Sensor 7 This device also allows being reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inoperable To ma...

Page 7: ...tamper switch 0 disabled 1 enabled 5 2nd Association Group Trigger Parameter 5 Size 1 Byte Default Value 0 Description This parameter defines the status of the water leakage that causes sending a BASI...

Page 8: ...tion Parameter 11 Size 2 Byte Default Value 0 Description Time a tamper alarm is delayed 0 32400 Seconds 12 Reporting tamper alarm cancellation Parameter 12 Size 1 Byte Default Value 1 Description Thi...

Page 9: ...e 43200 Description This parameter defines the time interval to send an unsolicited report If the value is set to 0 there will be no periodic reports sent to the controller However reports on temperat...

Reviews: