Setting
Description
0 - 255
Value
Parameter 12: High Humidity Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 4
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 255
Value
Parameter 13: Offset value for Mould danger notification
This value allows to increase the humidity threshold for mould danger notification by max 10%
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 10
%
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0
Setting
Description
1
– 4294967294
Reset all Parameter settings to their default settings.
4294967295
Completely factory reset sensor and send device reset locally notification.
Technical Data
Dimensions
34x34x16 mm
Hardware Platform
ZGM130S
IP Class
IP 20
Battery Type
1 * CR2477
Device Type
Notification Sensor
Generic Device Class
GENERIC TYPE SENSOR NOTIFICATION (0x07)
Specific Device Class
SPECIFIC TYPE NOTIFICATION SENSOR (0x01)
Network Operation
Reporting Sleeping Slave
Firmware Version
01.00
Z-Wave Version
07.12
Z-Wave Product Id
0371.0002.0009
Frequency
Europe - 868,4 Mhz
Maximum transmission
power
5 mW