Aeotec AEOEZWA009 Manual Download Page 6

Setting 

Description 

0 - 255 

Value 

Parameter 12: High Humidity Trigger BASIC Set Command Value 
This defines what BASIC command shall be sent out into association group 4

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

0 - 255 

Value 

Parameter 13: Offset value for Mould danger notification 
This value allows to increase the humidity threshold for mould danger notification by max 10%

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

0 - 10 

Parameter 255: Reset Parameter 
This parameter helps reset configuration parameters and the device to factory defaults

 

Size: 4 Byte, Default Value: 0 

Setting 

Description 

– 4294967294 

Reset all Parameter settings to their default settings. 

4294967295 

Completely factory reset sensor and send device reset locally notification. 

Technical Data 

Dimensions 

34x34x16 mm 

Hardware Platform 

ZGM130S 

IP Class 

IP 20 

Battery Type 

1 * CR2477 

Device Type 

Notification Sensor 

Generic Device Class 

GENERIC TYPE SENSOR NOTIFICATION (0x07) 

Specific Device Class 

SPECIFIC TYPE NOTIFICATION SENSOR (0x01) 

Network Operation 

Reporting Sleeping Slave 

Firmware Version 

01.00 

Z-Wave Version 

07.12 

Z-Wave Product Id 

0371.0002.0009 

Frequency 

Europe - 868,4 Mhz 

Maximum transmission 
power 

5 mW 

Summary of Contents for AEOEZWA009

Page 1: ...to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electronic equipment or batteri...

Page 2: ...owever it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to b...

Page 3: ...in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise y...

Page 4: ...o the controller when the temperature changes However periodic reports managed by configuration parameter 4 may still be active Size 1 Byte Default Value 20 Setting Description 0 disabled 1 100 1 10 d...

Page 5: ...Lower Watermark value This parameter defines a relative humidity If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5 Size 1 Byte Default Val...

Page 6: ...iguration parameters and the device to factory defaults Size 4 Byte Default Value 0 Setting Description 1 4294967294 Reset all Parameter settings to their default settings 4294967295 Completely factor...

Page 7: ...ation Command Class Version 2 highest granted security level Version Command Class Version 3 highest granted security level Security 2 Command Class Version 1 highest granted security level Supervisio...

Reviews: