 Available in selected Z-Wave Plus devices built upon 500 series technology and all devices built 

upon 700 series technology, SmartStart lets you setup Z-Wave devices in seconds.Using SmartStart enabled 
apps, simply scan the QR code on any compatible app to connect it to your Z-Wave gateway.

 

 

Product Description 

This device measures the three air quality parameters temperature, humidity and dew point and reports them to 
a central controller. Besides this, the device can directly control groups of other Z-Wave devices on over- and 
undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for 
temperature and humidity. The device wakes up every 15 minutes to measure the values and it will send 
unsolicited reports when values change. Additionally, the device will report all values on request. 
The AërQ Sensor is actively monitoring the danger of mould in a room based on the temperature and humidity 
and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking 
LED will indicate a mould condition. This local LED warning function is also available when the device is not 
included in any Z-Wave network and works stand alone. 

Prepare for Installation / Reset 

Please read the user manual before installing the product. 

In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make sure 

to reset the device into factory default. You can do this by performing an Exclusion operation as described 
below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to 
use the primary controller of the previous network to make sure the very device is excluded properly from this 
network. 

Reset to factory default 

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only 
be used when the primary controller is inoperable. 

Keep the button pressed for 10 seconds. Then the green LED will start blinking. Release the button, when the 
LED stops blinking. Your device is reset to factory default now. 

Safety Warning for Batteries 

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries 
of different charging level or different brands. 

Installation 

Just place the device on any flat surface. Please keep in mind that the temperature may be different in different 
locations inside the room. If placed too close to the heating both temperature, humidity and dew point values 
may be wrong. The device is IP 20 rated. This means that is must not be exposed to direct water (rain). It is 
safe to use the device in a humid environment such as a bathroom or dedicated washing facility. 

Inclusion/Exclusion 

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an 

existing wireless network

 to communicate with the devices of this network. This process is called 

Inclusion

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated 

by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion 
mode. Inclusion and Exclusion is then performed doing a special manual action right on the device. 

Inclusion 

1. Insert the battery. 
2. Press the button quickly three times in a row. 

Exclusion 

1. Press the button quickly three times in a row. 

 

Summary of Contents for AEOEZWA009

Page 1: ...to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electronic equipment or batteri...

Page 2: ...owever it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to b...

Page 3: ...in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise y...

Page 4: ...o the controller when the temperature changes However periodic reports managed by configuration parameter 4 may still be active Size 1 Byte Default Value 20 Setting Description 0 disabled 1 100 1 10 d...

Page 5: ...Lower Watermark value This parameter defines a relative humidity If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5 Size 1 Byte Default Val...

Page 6: ...iguration parameters and the device to factory defaults Size 4 Byte Default Value 0 Setting Description 1 4294967294 Reset all Parameter settings to their default settings 4294967295 Completely factor...

Page 7: ...ation Command Class Version 2 highest granted security level Version Command Class Version 3 highest granted security level Security 2 Command Class Version 1 highest granted security level Supervisio...

Reviews: