Setting 

Description 

disabled 

1 - 1000 

1/10 degree 

Parameter 6: Temperature Lower Watermark value 
This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC 
command is sent into Association Group 3

 

Size: 2 Byte, Default Value: 0 

Setting 

Description 

disabled 

200 - 1000 

1/10 degree 

Parameter 7: Humidity Upper Watermark value 
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a 
BASIC command is sent into Association Group 4

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

disabled 

1 - 90 

Parameter 8: Humidity Lower Watermark value 
This parameter defines a relative humidity. If the measured temperature drops below this relative humidity a 
BASIC command is sent into Association Group 5

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

disabled 

1 - 90 

Parameter 9: Low Temperature Trigger BASIC Set Command Value 
This defines what BASIC command shall be sent out into association group 3

 

Size: 1 Byte, Default Value: 255 

Setting 

Description 

0 - 255 

Value 

Parameter 10: High Temperature Trigger BASIC Set Command Value 
This defines what BASIC command shall be sent out into association group 2

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

0 - 255 

Value 

Parameter 11: Low Humidity Trigger BASIC Set Command Value 
This defines what BASIC command shall be sent out into association group 5

 

Size: 1 Byte, Default Value: 255 

Summary of Contents for AEOEZWA009

Page 1: ...to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electronic equipment or batteri...

Page 2: ...owever it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to b...

Page 3: ...in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise y...

Page 4: ...o the controller when the temperature changes However periodic reports managed by configuration parameter 4 may still be active Size 1 Byte Default Value 20 Setting Description 0 disabled 1 100 1 10 d...

Page 5: ...Lower Watermark value This parameter defines a relative humidity If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5 Size 1 Byte Default Val...

Page 6: ...iguration parameters and the device to factory defaults Size 4 Byte Default Value 0 Setting Description 1 4294967294 Reset all Parameter settings to their default settings 4294967295 Completely factor...

Page 7: ...ation Command Class Version 2 highest granted security level Version Command Class Version 3 highest granted security level Security 2 Command Class Version 1 highest granted security level Supervisio...

Reviews: