Setting
Description
1
Send Meter Report of energy (kWh)
2
Send Meter Report of wattage (W)
4
Send Meter Report of voltage (V)
8
Send Meter Report of current (A)
256
Send Multi Channel Meter Report of wattage (W) on Channel 1
512
Send Multi Channel Meter Report of wattage (W) on Channel 2
2048
Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096
Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536
Send Multi Channel Meter Report of voltage (V) on Channel 1
131072
Send Multi Channel Meter Report of voltage (V) on Channel 2
524288
Send Multi Channel Meter Report of current (A) on Channel 1
1048576
Send Multi Channel Meter Report of current (A) on Channel 2
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0
Setting
Description
1
Send Meter Report of energy (kWh)
2
Send Meter Report of wattage (W)
4
Send Meter Report of voltage (V)
8
Send Meter Report of current (A)
256
Send Multi Channel Meter Report of wattage (W) on Channel 1
512
Send Multi Channel Meter Report of wattage (W) on Channel 2
2048
Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096
Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536
Send Multi Channel Meter Report of voltage (V) on Channel 1
131072
Send Multi Channel Meter Report of voltage (V) on Channel 2
524288
Send Multi Channel Meter Report of current (A) on Channel 1
1048576
Send Multi Channel Meter Report of current (A) on Channel 2
Parameter 103: To set which reports need to be sent in Report group 3.
To set which reports need to be sent in Report group 3.
Size: 1 Byte, Default Value: 0