Aeotec AEOEZW132 Manual Download Page 3

7-11-2020

manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132

manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132

3/10

2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum
Nodes

Description

1

5

Z-Wave Plus Lifeline.When the load state of Dual Nano Switch (turn on/off the load) is changed, the
Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this
group.

2

5

Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the
Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main
controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2)

3

5

Send Basic Set (configured by parameter 81 ) to the associated nodes in Group 3 when the
external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified
successfully, which means that the value of Configuration parameter 120 should be non-zero, then
the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch.

4

5

Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external
switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified
successfully, which means that the value of Configuration parameter 121 should be non-zero, then
the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the

desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 3: Current Overload Protection.

Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A. 

Size: 1 Byte, Default Value: 1

Setting

Description

0

Disable

1

Enable

Parameter 4: Overheat protection.

Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 u2103. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

Disable

1

Enable

Parameter 20: Configure the output status after re-power on it.

Configure the output status after re-power on it. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

Last status

1

Always on

2

Always off

Summary of Contents for AEOEZW132

Page 1: ...ut Z Wave technology devices white papers etc please refer to www z wave info Product Description Aeotec Dual Nano Switch is a Z Wave Smart Switch specifically used to enable Z Wave command and contro...

Page 2: ...clusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Install the device according to the instructions 2 Press the b...

Page 3: ...the external switch S1 is operated Note The Switch Mode of external switch S1 should be identified successfully which means that the value of Configuration parameter 120 should be non zero then the B...

Page 4: ...g the external switch 2 to switch the loads Size 1 Byte Default Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 83 Configure the state of LED when it is in 3 modes Configure t...

Page 5: ...Enable Parameter 91 Set the threshold value of wattage Threshold change in wattage in terms of wattage to induce an automatic report Size 2 Byte Default Value 25 Setting Description 0 60000 The thersh...

Page 6: ...Channel 2 Parameter 102 To set which reports need to be sent in Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Repo...

Page 7: ...ription 0 Reset the parameter 111 113 Parameter 111 Set the interval of automatic report for Report group 1 Set the interval of automatic report for Report group 1 Size 4 Byte Default Value 10 Setting...

Page 8: ...ue 3 Setting Description 1 control the output loads of itself 2 control the other nodes 3 control the output loads of itself and other nodes Parameter 252 Lock unlock configuration parameters Lock unl...

Page 9: ...ene Supported Meter Type Electric Energy Firmware Updatable Updatable by Consumer by RF Electric Load Type Dimmable LEDElectronic with without DimmingFluorescent Non Dimming IncandescentInductiveLEDMa...

Page 10: ...ary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control re...