Aeotec AEOEZW132 Manual Download Page 10

7-11-2020

manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132

manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132

10/10

Controlled Command Classes

Basic

Hail

Explanation of Z-Wave specific terms

Controller

 — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall

controllers.

Slave

 — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller

 — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.

Inclusion

 — is the process of adding new Z-Wave devices into a network.

Exclusion

 — is the process of removing Z-Wave devices from the network.

Association

 — is a control relationship between a controlling device and a controlled device.

Wakeup Notification

 — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.

Node Information Frame

 — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by 

Z-Wave

Europe GmbH

. The product content is maintained by Z-Wave Europe GmbH , Supportteam, [email protected]. Last update of the product data: 2020-01-23

09:50:55

Summary of Contents for AEOEZW132

Page 1: ...ut Z Wave technology devices white papers etc please refer to www z wave info Product Description Aeotec Dual Nano Switch is a Z Wave Smart Switch specifically used to enable Z Wave command and contro...

Page 2: ...clusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Install the device according to the instructions 2 Press the b...

Page 3: ...the external switch S1 is operated Note The Switch Mode of external switch S1 should be identified successfully which means that the value of Configuration parameter 120 should be non zero then the B...

Page 4: ...g the external switch 2 to switch the loads Size 1 Byte Default Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 83 Configure the state of LED when it is in 3 modes Configure t...

Page 5: ...Enable Parameter 91 Set the threshold value of wattage Threshold change in wattage in terms of wattage to induce an automatic report Size 2 Byte Default Value 25 Setting Description 0 60000 The thersh...

Page 6: ...Channel 2 Parameter 102 To set which reports need to be sent in Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Repo...

Page 7: ...ription 0 Reset the parameter 111 113 Parameter 111 Set the interval of automatic report for Report group 1 Set the interval of automatic report for Report group 1 Size 4 Byte Default Value 10 Setting...

Page 8: ...ue 3 Setting Description 1 control the output loads of itself 2 control the other nodes 3 control the output loads of itself and other nodes Parameter 252 Lock unlock configuration parameters Lock unl...

Page 9: ...ene Supported Meter Type Electric Energy Firmware Updatable Updatable by Consumer by RF Electric Load Type Dimmable LEDElectronic with without DimmingFluorescent Non Dimming IncandescentInductiveLEDMa...

Page 10: ...ary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control re...

Reviews: