5/10

Parameter 87: Set appointment 2

Set the OFF time of output load. 

Size: 4 Byte, Default Value: 8327680

Setting

Description

0 - 60

The minute value of ON time

256 - 316

The hour value of ON time

65536 - 65543

The day value (Mon to Sun)

16777215

Disable the setting.

16777216

Enable the setting.

Parameter 90: Enables/disables parameter 91 and 92 below:

Enables/disables the function of parameter 91 and 92. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

Disable

1

Enable

Parameter 91: Set the threshold value of wattage.

Threshold change in wattage (in terms of wattage) to induce an automatic report. 

Size: 2 Byte, Default Value: 25

Setting

Description

0 - 60000

The thershold value range is 0 to 60000

Parameter 92: Set the threshold value of wattage.

Threshold change in wattage (in terms of percentage) to induce an automatic report. 

Size: 1 Byte, Default Value: 5

Setting

Description

0 - 100

The thershold value range is 0 to 100

Parameter 100: Set parameter 101-103 to default value.

Set parameter 101-103 to default value. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

Reset the parameter 101-103

Parameter 101: To set which reports need to be sent in Report group 1.

To set which reports need to be sent in Report group 1. 

Size: 4 Byte, Default Value: 0

Summary of Contents for AEOEZW132

Page 1: ...ut Z Wave technology devices white papers etc please refer to www z wave info Product Description Aeotec Dual Nano Switch is a Z Wave Smart Switch specifically used to enable Z Wave command and contro...

Page 2: ...clusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Install the device according to the instructions 2 Press the b...

Page 3: ...the external switch S1 is operated Note The Switch Mode of external switch S1 should be identified successfully which means that the value of Configuration parameter 120 should be non zero then the B...

Page 4: ...g the external switch 2 to switch the loads Size 1 Byte Default Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 83 Configure the state of LED when it is in 3 modes Configure t...

Page 5: ...Enable Parameter 91 Set the threshold value of wattage Threshold change in wattage in terms of wattage to induce an automatic report Size 2 Byte Default Value 25 Setting Description 0 60000 The thersh...

Page 6: ...Channel 2 Parameter 102 To set which reports need to be sent in Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Repo...

Page 7: ...ription 0 Reset the parameter 111 113 Parameter 111 Set the interval of automatic report for Report group 1 Set the interval of automatic report for Report group 1 Size 4 Byte Default Value 10 Setting...

Page 8: ...ue 3 Setting Description 1 control the output loads of itself 2 control the other nodes 3 control the output loads of itself and other nodes Parameter 252 Lock unlock configuration parameters Lock unl...

Page 9: ...ene Supported Meter Type Electric Energy Firmware Updatable Updatable by Consumer by RF Electric Load Type Dimmable LEDElectronic with without DimmingFluorescent Non Dimming IncandescentInductiveLEDMa...

Page 10: ...ary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control re...

Reviews: