IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the

desired value minus 256. For example: To set a parameter to 200

it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the

same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 3: Current Overload Protection.

Over current protection. Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A)

Size: 1 Byte, Default Value: 1

Setting

Description

0

Disable

1

Enable

Parameter 4: Overheat protection.

Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100°C.

Size: 1 Byte, Default Value: 0

Setting

Description

0

Disable

1

Enable

Parameter 20: Configure the output status after re-power on it.

Configure the output status after re-power on it.

Size: 1 Byte, Default Value: 0

Setting

Description

0

Last status

1

Always on

2

Always off

Parameter 80: To set which notification would be sent to the associated devices (Group 1)

To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed.

Size: 1 Byte, Default Value: 0

Setting

Description

0

Send Nothing

1

Send Hail CC

2

Send Basic CC report

3

Send Multilevel Switch report

4

Send Hail CC when using the manual switch to change the load state.

Parameter 81: To set which notification would be sent to the associated nodes in association group 3

To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads.

Size: 1 Byte, Default Value: 1

Setting

Description

0

Send Nothing

1

Send Basic Set CC

Parameter 82: To set which notification would be sent to the associated nodes in association group 4

To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads.

Size: 1 Byte, Default Value: 1

Setting

Description

0

Send Nothing

1

Send Basic Set CC

Parameter 83: Configure the state of LED

Configure the state of LED when it is in 3 modes

Size: 1 Byte, Default Value: 0

Summary of Contents for AEOEZW116

Page 1: ...other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z W...

Page 2: ...ery device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when th...

Page 3: ...pper wires for external manual switch Use the wire stripper cut the metallic part of the connection wire and make sure the length of the metallic part is about 5mm Note All connection wires needs to b...

Page 4: ...V power wire All above wiring diagrams show that the Nano Switch uses 2 Way or momentary button switches as the external manual switch for 2 Way connection The below diagram will show you that the Nan...

Page 5: ...r device Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device...

Page 6: ...atus 1 Always on 2 Always off Parameter 80 To set which notification would be sent to the associated devices Group 1 To set which notification would be sent to the associated devices Group 1 when the...

Page 7: ...ter 87 Set appointment 2 Set appointment 2 Size 4 Byte Default Value 2293760 Setting Description 0 60 The minute value of ON time 256 316 The hour value of ON time 65536 65543 The day value Mon to Sun...

Page 8: ...t group 3 To set which reports need to be sent in Report group 3 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Report of voltage V 2 Send Meter Report of current A 4 Send Meter Report o...

Page 9: ...ay switch mode 3 2 state switch mode Parameter 122 Set the control destination for external switch S1 Set the control destination of the external switch Size 1 Byte Default Value 3 Setting Description...

Page 10: ...Activation Scene Actuator Conf Meter Association Grp Info Device Reset Locally Zwaveplus Info Configuration Alarm Manufacturer Specific Powerlevel Firmware Update Md Clock Association Version Hail Co...

Page 11: ...issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2021 Z Wa...

Reviews: