The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the same device. Used batteries 
contain hazardous substances and should not be disposed of with household waste! 

Battery Type:  2 * CR123A 

Installation Guidelines 

You can install the Multisensor wherever you want thanks to the enclosed accessories. You can use either the mounting arm or the tape to 

install the Multisensor. With the tape the Multisensor will be static in that position. If you want to use the mounting arm simply install the 

mounting arm wherever you want and screw in the Multisensor. With the mounting arm you will be able to adjust the Multisensor exactly in 
whatever direction you wish. 

Behavior within the Z-Wave network 

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to 

communicate with the devices of this network. This process is called 

Inclusion

. Devices can also leave a network. This process is 

called 

Exclusion

. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion 

respective inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode. 
Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network - i.e. being 

excluded - sets the device back to factory default. 

If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this 
device will fail. If the controller being included was a primary controller, it has to be reset first. 

Power on the MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action Button. Set the primary controller into 
inclusion mode (If yo

u don’t know how to do this, refer to its manual). Press the Action Button. If the inclusion is successful, the 

MultiSensor’s LED will be kept turning on for 8 seconds when you short press the Action Button. If the LED is still in slow blink, you need to 
repeat the process from setting the controller into inclusion mode onward. If you want to reset the Multisensor to its factory default state you 

can do this by pressing and holding the action button for at least 20 seconds. During this time the LED will blink faster and faster. After that 
time the LED will stay solid for 2 seconds to indicate success. 

Summary of Contents for AEOEZW100

Page 1: ...link you need to repeat the process from setting the controller into inclusion mode onward Please refer to the chapters below for detailed information about all aspects of the products usage What is Z...

Page 2: ...ontrollers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers Product description Aeon Labs MultiSensor is a rou...

Page 3: ...xclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exc...

Page 4: ...and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame There are 2 ways to s...

Page 5: ...s when re power on battery mode the MultiSensor Value Description 0 disable Default 1 enable default PIR time Parameter Number 3 Parameter Size 2 The default PIR time is 4 minutes The Multisensor will...

Page 6: ...orting Parameter Number 40 Parameter Size 1 Enable disable the selective reporting only when measurements reach a certain threshold or percentage set in 41 44 below This is used to reduce network traf...

Page 7: ...Size 1 The battery activity will be reduced at low temperatures 15 degrees Celsius and below which will lead to the product may not work normally It is recommended to use USB power at low temperatures...

Page 8: ...reserved 2 0 7 reserved 3 0 7 reserved 4 0 Battery 1 3 reserved 4 ultraviolet 5 temperature 6 Humidity 7 Luminance Set 111 113 to default Parameter Number 110 Parameter Size 1 Value Description Param...

Page 9: ...e Meta Data version 2 Battery version 1 Association version 2 Device Reset Locally version 1 Controlled Command Classes Device Reset Locally version 1 Technical Data Battery Type 2 CR123A Explorer Fra...

Page 10: ...twork Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able...

Reviews: