Value 

Description 

Threshold change in luminance to induce an automatic report. (Parameter Number 43, Parameter Size 2)

Default Value = 100 LUX 

Value 

Description 

Threshold change in battery level to induce an automatic report. (Parameter Number 44, Parameter Size 2)

The accuracy is 0.1. The 

high byte is the part of integer, the low byte is the fractional part. 

Value 

Description 

Threshold change in ultraviolet to induce an automatic report. (Parameter Number 45, Parameter Size 2)

Default Value = 2 

Value 

Description 

Enable/disable to send the alarm report of low temperature(<-15

) (Parameter Number 46, Parameter Size 1)

The battery activity will 

be reduced at low temperatures (-15 degrees Celsius and below), which will lead to the product may not work normally. It is recommended 
to use USB power at low temperatures. 

Value  Description 

disable (Default) 

enable (The MultiSensor will report the Multi Level Temperature CC with the value=0xFFFF to controller if the current temperature is less than -15

). 

(Parameter Number 100, Parameter Size 1)

Set 101-103 to default. 

Value 

Description 

Which report needs to be sent in Report group 1 (Parameter Number 101, Parameter Size 4)

 

Value 

Description 

0-7 = reserved 

0-7 = reserved 

0-7 = reserved 

0 = Battery 1-3 = reserved 4 = ultraviolet 5 = temperature 6 = Humidity 7 = Luminance 

Which report needs to be sent in Report group 2 (Parameter Number 102, Parameter Size 4)

 

Value 

Description 

Summary of Contents for AEOEZW100

Page 1: ...link you need to repeat the process from setting the controller into inclusion mode onward Please refer to the chapters below for detailed information about all aspects of the products usage What is Z...

Page 2: ...ontrollers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers Product description Aeon Labs MultiSensor is a rou...

Page 3: ...xclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exc...

Page 4: ...and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame There are 2 ways to s...

Page 5: ...s when re power on battery mode the MultiSensor Value Description 0 disable Default 1 enable default PIR time Parameter Number 3 Parameter Size 2 The default PIR time is 4 minutes The Multisensor will...

Page 6: ...orting Parameter Number 40 Parameter Size 1 Enable disable the selective reporting only when measurements reach a certain threshold or percentage set in 41 44 below This is used to reduce network traf...

Page 7: ...Size 1 The battery activity will be reduced at low temperatures 15 degrees Celsius and below which will lead to the product may not work normally It is recommended to use USB power at low temperatures...

Page 8: ...reserved 2 0 7 reserved 3 0 7 reserved 4 0 Battery 1 3 reserved 4 ultraviolet 5 temperature 6 Humidity 7 Luminance Set 111 113 to default Parameter Number 110 Parameter Size 1 Value Description Param...

Page 9: ...e Meta Data version 2 Battery version 1 Association version 2 Device Reset Locally version 1 Controlled Command Classes Device Reset Locally version 1 Technical Data Battery Type 2 CR123A Explorer Fra...

Page 10: ...twork Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able...

Reviews: