Value
Description
Threshold change in luminance to induce an automatic report. (Parameter Number 43, Parameter Size 2)
Default Value = 100 LUX
Value
Description
Threshold change in battery level to induce an automatic report. (Parameter Number 44, Parameter Size 2)
The accuracy is 0.1. The
high byte is the part of integer, the low byte is the fractional part.
Value
Description
Threshold change in ultraviolet to induce an automatic report. (Parameter Number 45, Parameter Size 2)
Default Value = 2
Value
Description
Enable/disable to send the alarm report of low temperature(<-15
℃
) (Parameter Number 46, Parameter Size 1)
The battery activity will
be reduced at low temperatures (-15 degrees Celsius and below), which will lead to the product may not work normally. It is recommended
to use USB power at low temperatures.
Value Description
0
disable (Default)
1
enable (The MultiSensor will report the Multi Level Temperature CC with the value=0xFFFF to controller if the current temperature is less than -15
℃
).
(Parameter Number 100, Parameter Size 1)
Set 101-103 to default.
Value
Description
Which report needs to be sent in Report group 1 (Parameter Number 101, Parameter Size 4)
Value
Description
1
0-7 = reserved
2
0-7 = reserved
3
0-7 = reserved
4
0 = Battery 1-3 = reserved 4 = ultraviolet 5 = temperature 6 = Humidity 7 = Luminance
Which report needs to be sent in Report group 2 (Parameter Number 102, Parameter Size 4)
Value
Description