41
The diagram below sums up the signs of the power as a function of the
phase angle between V and I:
Quadrant 1: Active power P
sign + (power consumed)
Quadrant 2: Active power P
sign - (power generated)
Quadrant 3: Active power P
sign - (power generated)
Quadrant 4: Active power P
sign + (power consumed)
4.2.13 Active AC+DC Power Measurements
Measurement
Range (2) (4)
5 to
9999W
10.00 to
99.99kW
100.0 to
999.9kW
1000 to
1500kW (1)
Specified
Measurement
Range
1 to 100% of the
measurement range
0 to 100%
of the measurement range
Accuracy (3)
1000A
± (2% R +10cts)
1000 to 1500A
± (2.5% R +10cts)
1000A
± (2% R +3cts)
1000A to 1500A
± (2.5% R +3cts)
Resolution
1W
10W
100W
1000W
Note (1) - Display of OL above 1500kW in single-phase (1000V x 1500A)
- Bandwidth in AC in voltage = 3 kHz, in current = 2 kHz
Notes (2), (3), (4), 5 and 6 of the previous § apply.
Consumed
Generated
www.
GlobalTestSupply
.com
Find Quality Products Online at: