4.2.2
AC Voltage Measurement
Measurement
Range
0.15 to
99.99V
100.0 to
999.9V
1000V RMS
1400V peak (1)
Specified
Measurement
Range (2)
0 to 100% of the measurement range
Accuracy
0.15 to 9.99V
± (1% R +10cts)
10.00 to 99.99V
± (1% R +3cts)
± (1% R +3cts)
Resolution
0.01V
0.1V
1V
Input Impedance
10M
Ω
Note (1)
The display indicates "OL" above 1000V (1400V in PEAK mode).
Above 1000V (RMS), a repetitive beep indicates that the voltage
being measured is greater than the safety voltage for which the
device is guaranteed. The display indicates "OL".
- Bandwidth in AC = 3 kHz
Note (2)
Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to show "----" on the display.
Specific Specifications in MAX/MIN mode
(from 10Hz to 1kHz, and from 0.30V in AC):
Accuracy: add 1% R to the values of the table above.
Capture of the extreme: approximately 100ms.
4.2.3
AC+DC Voltage Measurement
Measurement Range (2)
0.15 to
99.99V
100.0 to
999.9V
1000V RMS (1)
1400V peak
Specified Measurement
Range
0 to 100% of the measurement range
Accuracy
0.15 to 9.99V
± (1% R +10cts)
10 to 99.99V
± (1% R +3cts)
± (1% R +3cts)
Resolution
0.01V
0.1V
1V
Input impedance
10M
Ω
Note (1)
The display indicates "OL" above 1000V (1400V in PEAK mode).
Above 1000V (DC or RMS), a repetitive beep indicates that the
voltage being measured is greater than the safety voltage for which
the device is guaranteed.
- Bandwidth in AC = 3 kHz
Note (2) Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to "----" on the display.