38
4.2.6
AC+DC Intensity Measurement
Measurement
Range (2)
0.15 to
99.99A
100.0 to
999.9A
AC: 1000
DC or PEAK:
1000 to 1500A (1)
Specified
Measurement
Range
0 to 100% of the measurement range
Accuracy (2)
(zero corrected)
± (1% R+10cts) ± (1% R +3cts)
1500A
± (1.5% R +3cts)
Resolution
0.01A
0.1A
1A
Note (1) In DC, the display indicates "+OL" above +3000A and "+-OL" above -
3000A in REL mode. The "-" and "+" signs are managed (polarity).
In AC and AC+DC, the display indicates "+OL" above 1500A in PEAK
mode. The "-" and "+" signs are not managed.
- Bandwidth in AC = 2 kHz
Note (2) In AC, any value between zero and the min. threshold of the
measurement range (0.15A) is forced to show "----" on the display.
-
Residual current at zero:
-
In DC: depends on the remanence. This can be corrected by the
"DC zero" function of the HOLD button
-
In AC: <150mA
Specific Specifications in MAX/MIN mode
(from 10Hz to 1kHz, and from 0.30A in AC):
Accuracy: add ± (1.5% L+0.5A) to the values in the tables above.
PEAK capture time: 1ms min. to 1.5ms max.
Specific characteristics in PEAK mode in current
(from 10Hz to 400Hz in AC and AC+DC):
Accuracy: add 1.5% R to the values in the tables above.
PEAK capture time: 1ms min. to 1.5ms max.
4.2.7 True In
R
ush
®
Measurement
Measurement Range
10 to 1000A
AC
10 to 1500A
DC
Specified Measurement Range
0 to 100% of the measurement range
Accuracy
± (5% R +5cts)
Resolution
1A
Specific Specifications in PEAK mode in True InRush
®
(from 10Hz to 1kHz):
Accuracy: add ± (1.5% R +0.5A) to the values in the table above.
PEAK capture time: 1ms min. to 1.5ms max.
www.
GlobalTestSupply
.com
Find Quality Products Online at: