Statement of Compliance

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments 

certifies that this instrument has been calibrated 
using standards and instruments traceable to 
international standards.

We guarantee that at the time of shipping your 
instrument has met its published specifications.

An NIST traceable certificate may be 
requested at the time of purchase, or obtained 
by returning the instrument to our repair and 
calibration facility, for a nominal charge.

The recommended calibration interval for this 
instrument is 12 months and begins on the date of 
receipt by the customer. For recalibration, please 
use our calibration services. Refer to our repair 
and calibration section at 

www.aemc.com

.

Serial #: 

 ________________________________

Catalog #:   ______________________________
Model #:  8335

Please fill in the appropriate date as indicated:

Date Received:  _________________________________

Date Calibration Due: 

 _______________________

Chauvin Arnoux

®

, Inc.

d.b.a AEMC

®

 Instruments

www.aemc.com

Summary of Contents for 2136.20

Page 1: ...QUICK START USER GUIDE 8335 PowerPad IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years...

Page 2: ...ent to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibratio...

Page 3: ...aView User Manual NiMh Battery installed Kits will also include order dependent 4 MN93 BK current probes 4 MN193 BK current probes 4 SR193 BK current probes 4 AmpFlex 193 24 BK 24 current sensors 4 Am...

Page 4: ...input Harmonics Mode Displays the harmonics in percent and value ratios for voltage current and power for each harmonic through the 50th Determines harmonic current produced by non linear loads Analyz...

Page 5: ...voltage inputs 7 USB port 8 Input for external power supply and battery charging 9 Confirm Enter button 10 Navigation buttons 11 Six mode buttons see chart left Connection Terminals 3 1 2 1 Four 4 cu...

Page 6: ...voltage and current curves Calculation Methods Determines if harmonics are used or not used in calculations of reactive quantities power and energy With harmonics Harmonics are taken into account when...

Page 7: ...2 L3 and N Disconnecting Proceed in the reverse order to connecting always finishing by disconnecting the ground and or neutral when distributed Disconnect the leads and press the button to turn the i...

Page 8: ...older view to launch the Dataview setup program NOTE For more information on using DataView refer to the Model 8335 user manual that is supplied on the USB stick Updating Software Firmware To provide...

Page 9: ...certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 60...

Page 10: ...he one year period you may return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or r...

Page 11: ...NOTES...

Page 12: ...10 13 99 MAN 100392 v2 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Reviews: