Charging the Battery

Fully charge the battery before the first use.
The batteries automatically begin recharging when the instrument is connected to AC power. 
Only use the supplied AC power adapter to recharge the batteries.

 

 

NOTE: 

A full recharge of a completely discharged battery takes 5 hours approx.

120V ± 10%, 60Hz
230V ± 10%, 50Hz

To recharge the battery:

•  Connect the supplied power 

cord to the instrument and AC 
power.

•  The 

 button lights and will 

go out when the power cord is 
disconnected.

Button Functions

BUTTON

DESCRIPTION

Return to the choice of measurement view.

Configure the PowerPad

®

 (SET-UP).

Take a snapshot of the current screen or access screens already stored in the memory.  

Record associated waveform and power measurement data.

Get help on the current display functions, in the language chosen by the user.

Transients or Inrush Current:

•  Sets and views transient and inrush current waveforms associated with rapid changes in input

Harmonics Mode:

•  Displays the harmonics in percent and value ratios for voltage, current and power for each 

harmonic through the 50th

•  Determines harmonic current produced by non-linear loads

•  Analyzes the problems caused by harmonics according to their order  

(heating of neutrals, conductors, motors, etc)

Waveforms Mode:

•  Displays voltage and current waveforms or vector representation

•  Identifies signal distortion signatures

•  Displays of amplitude and phase unbalance for voltage and current 

•  Checks connections for correct phase order

Alarm Events:

•  Provides a list of the alarms recorded according to the thresholds programmed during 

configuration

•  Logs interruption with half-cycle resolution

•  Determines energy consumption exceedances

•  Stores value, duration, date, time and set point for up to 4096 events

Trend Mode:

•  Lists all recording trends and views them on the display 

(Urms, Vrms, Arms, etc)

Power / Energy:

•  Displays power levels and the associated parameters (power factor, displacement and tangent)

•  Energy monitoring

•  Four quadrant measurement to discern produced/consumed active energies and inductive/capaci-

tive reactive energies

Summary of Contents for 2136.20

Page 1: ...QUICK START USER GUIDE 8335 PowerPad IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years...

Page 2: ...ent to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibratio...

Page 3: ...aView User Manual NiMh Battery installed Kits will also include order dependent 4 MN93 BK current probes 4 MN193 BK current probes 4 SR193 BK current probes 4 AmpFlex 193 24 BK 24 current sensors 4 Am...

Page 4: ...input Harmonics Mode Displays the harmonics in percent and value ratios for voltage current and power for each harmonic through the 50th Determines harmonic current produced by non linear loads Analyz...

Page 5: ...voltage inputs 7 USB port 8 Input for external power supply and battery charging 9 Confirm Enter button 10 Navigation buttons 11 Six mode buttons see chart left Connection Terminals 3 1 2 1 Four 4 cu...

Page 6: ...voltage and current curves Calculation Methods Determines if harmonics are used or not used in calculations of reactive quantities power and energy With harmonics Harmonics are taken into account when...

Page 7: ...2 L3 and N Disconnecting Proceed in the reverse order to connecting always finishing by disconnecting the ground and or neutral when distributed Disconnect the leads and press the button to turn the i...

Page 8: ...older view to launch the Dataview setup program NOTE For more information on using DataView refer to the Model 8335 user manual that is supplied on the USB stick Updating Software Firmware To provide...

Page 9: ...certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 60...

Page 10: ...he one year period you may return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or r...

Page 11: ...NOTES...

Page 12: ...10 13 99 MAN 100392 v2 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Reviews: