UT12-000 Universal Encoder/Decoder
SM40 Installation and Operation Manual
May 15, 2012 Rev: 5.00
Page 3-2
ENG-FORM: 806-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
3.3.2 Alphanumeric
Pushbuttons
The Alphanumeric Pushbuttons (
–
, , ) are used for entry of tones and data. The and keys also
function as left (
←
) and right (
→
) arrows to be used for scrolling.
To enter an alphanumeric character for Ids or names, repeatedly press a number button until the desired
character is displayed, then press a different numbered button or the right arrow button to advance to the
next space. Press the left arrow button to change a previous character. Press the
button to save
the tone ID name. The button has the ,
, and _ (space) characters, and has the , , and
characters.
3.3.3 Function
Pushbuttons
The basic functions of the operator controls are listed below. Detailed operation will be discussed in
sections 3.4 through 3.8.
:
Used to cancel operation and reset control head display. Also used to turn off the external
alert key if on. May display a brief software message when no other activity is in progress.
:
Used to transmit CCIR phone activation sequence. Automatically selects DTMF as mode
type after sequence is sent. After disconnect or 20 seconds after loss of carrier the mode
type returns to CCIR.
:
Used to change the system tone type, enter DATA mode, and turn the scrambler on or off.
:
Used to store tone information in memory.
:
Used to recall tone information from memory.
:
Used to complete operation or to check current buffer status.
:
Used to disconnect UT12 from CCIR network, transmit call breakdown sequence, and turn off
headphone audio.
:
Used to send status information to base station. Also serves as a function key for entry into
configuration mode, and entry into serial load mode.
:
Used to transmit the tone(s) in the selected transmit buffer.