UT12-000 Universal Encoder/Decoder
SM40 Installation and Operation Manual
May 15, 2012 Rev: 5.00
Page 3-7
ENG-FORM: 806-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2) If the tone sequence is to be stored at location
XX
, press
,
3) If the information is to be stored in a different location, press the two digits corresponding to that
location. If there is no information stored there, <
FREE>STORE?
is displayed. Press
to
store the information.
4) If there is information present,
<FULL>STORE?
Will be displayed. Press
and the display
will show
OVERWRITE=Enter
5) Press
again to write the last sequence into that memory location. If the location is locked,
XX*Tones LOCKED
will be displayed. Press
to exit without storing the tone sequence.
Keypad numbers or arrows may be used to find another location to store the information. After
is pressed, the control head will prompt the user for the tone ID name, to be entered using
the alphanumeric pushbuttons. To bypass this option press
.
3.4.2.3
Recalling a Tone Sequence
The operator is able to recall any tone sequence that has been stored: for example, to display the tone
sequence that is stored in location 57, push
.
The information displayed will depend upon the selections made on the control head. When the control
head is in ID mode, the ID of the tone will be displayed, and when the control head is in TX or RX mode,
the tone sequence will be displayed. Tone information can be scrolled up or down by using the
←
and
→
buttons.
When the tone information is displayed, the operator may press
to select and transmit the CCIR
tone sequence, or press
to cancel the recall operation. When the control head
Display
switch is
moved between ID and RX or TX, the tone sequence or ID will be updated within one second.
By pressing
, the control head will display the most recent transmitted tone sequence. The
operator can scroll through last five transmitted tones using the
←
and
→
buttons, and transmit the
displayed tone by pressing
.
To recall the UT12’s Unit ID, press
. The control head will display
Unit ID:UUUUU
.
3.4.2.4
Deleting Information from Tone Location
To delete the tone sequence and tone ID from a tone storage location:
1) Press
until the control head displays
RECALL TONES
,
2) Press XX, (Where XX is a number from 00 to 99)
3) Press
If the tone is locked the control head will display
XXTonesLOCKED
If the tone is not locked the control head will display
DELETE Tone?
4) Press
to delete the tone sequence and tone ID. The control head will display
Tone XX DELETED
.
5) Press
to cancel the operation.