SET KEYPAD IN PROGRAMMING MODE WITH MASTER CODE
It is always necessary to set the keypad in programming mode for feature programming
The keypad is in normal operation after power-up delay. Set it in programming mode with Master
Code and validate it with
.
MASTER CODE
VALIDATION
NOTE:
a) For the owner’s convenience in programming at the first time, a Master Code 0 0 0 0 has been
put into the keypad before exit-factory. It is
NOT
a default code. For security reason, owner
should program a personal Master Code to replace it after the keypad is owned.
b) The Mains LED (amber) is ON after the keypad confirms it in programming mode with 2 beeps.
c)
DO NOT
turn off power while the keypad is in programming mode. Otherwise, it may cause error
to the data in memory.
PROGRAMMING & OPERATION
PROGRAMMING SUMMARY CHART
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code
4-8 Digits
MASTER CODE
NIL
0 2
Super User
Code
4-8 Digits
SUPER USER CODE
NIL
0 3
Common User
Code for
O/P 1
4-8 Digits
COMMON USER CODE 1
NIL
0 4
Common User
Code for
O/P 2
COMMON USER CODE 2
NIL
10
User
Codes / Cards for
O/P 1
CODE 1
-
MEDIA:
1---EM Card
2---Private User Code
3---EM Card+Sec User Code
4---EM Card+Com User Code
5---Deletion of User Code
CODE 2
-
USER ID:
000-999---Group 1(10)
CODE 3
-
USER CODES /
Cards: 4-8 Digits / Cards
CODE1
CODE2
CODE3
NIL
4 0
Visitor Codes
CODE 1
-
VISITOR ID:
01-50
CODE 2
-
VALID PERIOD:
00---One Time
01-99 Hours
CODE 3
-
VISITOR CODE:
4-8 Digits
CODE1
CODE2
CODE3
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds,
START TIME:
00:00-23:59
STOP TIME:
00:00-23:59
5 6
Start & Stop Times
for Inhibition
STOP TIME
START TIME
NIL
CURRENT REAL TIME:
00:00-23:59
5 5
Real-Time-Clock
CURRENT TIME
NIL
Momentary
O/P MODE & TIME
5 Seconds
Pacifier Tone ON-OFF
7 1
FUNCTION MODE:
0---NO Notification
2---2 Short Beeps
1---1 Second Long Beep
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE
Mode = 1,
ON
7 2
Output Announcer
FUNCTION MODE
7 3
Standby LED Flashing
FUNCTION MODE
Mode = 1,
Flashing ON
Mode = 1
1 Second
Long Beep
Pacifier Tone
6 0
Personal Safety &
Lock-Up
LOCK-UP CODE:
1---10 Trial, Lock-Up 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Up 15
Minutes
00---No Lock-Up
LOCK-UP CODE
Code = 1,
10 Trials,
Lock-Up 60
Seconds
7 0
Code Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
ENTRY MODE
Mode =
2, Manual
Mode
POWER-UP THE KEYPAD
The keypad gives power-up delay of 1 minute after power has been applied. It is the time frame
designed for setting the keypad to programming mode with DAP code. See the details of
“DAP
CODE – 2 8 2 8”
below.
1) The keypad gives continuous beeps for 1 minute after power-up.
2) The power-up delay can be stopped instantly with
if the delay beep is found annoying
and setting the keypad to programming mode with DAP code is not required.
3) The keypad will set itself to Normal Operation Mode automatically after the 1 minute power-up
delay expired or it is stopped with
.
POWER-UP DELAY STOP VALIDATION
Summary of Contents for DK-2890
Page 2: ......
Page 48: ...AEI PROTECT ON SYSTEMS LIMITED www apo hk com...