Paper Filter
VAMPYR CE...
T
E No. 900.087.600
ET No. 668.901.268
Paper Filter Size 28
Microfilter
ET No. 668 100 151
Carrying and Storage
To make the appliance easier to store and carry,
slide the floor nozzle into the tool rail.
Parking System
For storing the suction tube and nozzle during
short pauses in use. The bracket on the nozzle is
slid into the parking rail on the appliance.
What to do, if ...
... the nozzle is hard to push
Turn down the power. Cleaning performance
will not be affected in this case.
... the motor thermal overload protection
device triggers
If the motor becomes overloaded, e.g. as the
result of the filter bag being full or a blocked
accessory, the thermal overload protection
device will shut down the motor. Turn off the
appliance, unplug from the mains, and allow the
motor to cool down.
Check paper filter bag, suction tube and suction
hose, remove any blockage.
The appliance can be turned on again after
approximately 30 minutes.
... the fuse has blown
The fuse may blow if you use other high power
electrical appliances on the same electrical cir-
cuit at the same time as the vacuum cleaner is
in use.
This may be prevented by setting the electronic
power regulator to minimum before turning on
the appliance and increasing the power setting
after switching on.
Your vacuum cleaner is equipped with an
electronic soft start controller that reduces
the start up current of the motor, this avoids
the mains fuse blowing under normal circum-
stances. As a result, at the lowest power set-
ting the appliance may have a start delay of
approx. 4 seconds.
… the paper filter is damaged at some stage
and the HEPA filter is dirtied
Remove the HEPA filter, clean (tap out) and
replace.
Insert new paper filter.