setpoint, the SST becomes smaller and the ramp is always crossed
once fully.
NOTE
Setting AN1, SST and T
0
independently
When a bus module or Thyro-Tool Family are used,
parameters AN1, SST and T
0
can be set independently of
one another.
• Setting potentiometer TRAFO ADAPTION R201 to left stop.
> At <30°el the device automatically switches to a faster Takt operati-
on with T0 = 5 periods without SST. Then terminal X2.7 can be used
as control input for switch operation.
When using the synchronization options, via R201 must
be set parameter AN1 >30° el (T
0
= 1000ms).
Analog output (setting aid)
10.0mA / 5V
100°el
6.0mA / 3,0V
60°el Thyro-A 1A (default)
9.0mA / 4,5V 90°el Thyro-A 2 & 3A (default)
3.0mA / 1,5V
30°el
2.5mA / 1,25V
0°el
4.3.3
Setting maximum load value with control end U, U
2
and P
control
For ...H RL1 and ...H RLP1
With potentiometer R202 SCALE SETPOINT, the maximum voltage
(for U, U2 control) or the maximum power (for P control) is set on the
load, depending on the control mode *
1
. If no P control is set, the po-
tentiometer works as voltage limitation. The end value of the control
characteristic is adapted accordingly (see following table).
Analog output: X2.9 (+); X2.5 (ground)
*
1
only for ...H RLP
• Set maximum load value (of U or P) at control end on potentiometer
R202 SCALE SETPOINT.
Summary of Contents for THYRO-A
Page 28: ...28 Possible settings in THYRO TOOL FAMILY ...
Page 89: ...89 EN 10 Type overview Thyro A 1A 16 H 30 H Thyro A 1A 45 H 60 H ...
Page 90: ...90 75 190 Thyro A 1A 100 H Thyro A 1A 130 H 170 H M 10 for grounding ...
Page 92: ...92 Thyro A 1A 495A 650A Thyro A 1A 1000A 1500 A ...
Page 96: ...96 Thyro A 2A 495 650HF Thyro A 2A 1000 1500HF ...
Page 97: ...97 EN Dimension drawing Thyro A 3A with 16A 30A The dimension drawings are for type H RLP1 ...
Page 98: ...98 Dimension drawing Thyro A 3A with 45A 60A The dimension drawings are for type H RLP1 ...
Page 99: ...99 EN Dimension drawing Thyro A 3A with 100A The dimension drawings are for type H RLP1 ...
Page 100: ...100 Dimension drawing Thyro A 3A with 130A 170A The dimension drawings are for type H RLP1 ...
Page 101: ...101 EN Dimension drawing Thyro A 3A with 280A The dimension drawings are for type H RLP1 ...
Page 103: ...103 EN Thyro A 3A 1000 1500HF Thyro A 3A 495 650HF ...