15
for the qualified installer
2.11 Special accessories
Jet regulator „SR“ for use in the jet-regulator screw fitting M/M4.
MTH 350 / MTH 440: SR 3 Order-No. 14 35 0
with output regulator.
MTH 570: SR 5 Order-No. 7 05 8
Only non pressurised taps can be used for this appliance!
– AHo 40 MTH - non pressurised wall fitting
Order-No. 18 54 74
– AHu 40 MTH - non pressure type sink/basin tap
Order-No. 18 54 75
– AHEu 40 MTH - non pressure type single lever mixer tap with pull-up plug
Order-No. 18 54 76
2.12 Technical data
(the data on the unit identification plate are applicable)
Table 1
Table
Designation as
Areas of application for different water analysis reference temperatures
Standard
at 15 °C
at 20 °C
at 25 °C
resistance
conductivity
conductivity
Ω
cm
mS/m
µS/cm
≥
1100
≤
90,9
≤
909
≥
970
≤
103
≤
1030
≥
900
≤
111
≤
1110
1) Specific electrical conductivity und specific electrical resistance
Type
MTH 350
MTH 440
MTH 570
Design
open
open
open
Configuration
under-sink •
•
•
over-sink •
•
•
Reated pressure
MPa 0
0
0
Rated capacity
l 0,1
0,1
0,1
Weight
kg 1,4
1,4
1,4
Rated power by 230 V
kW 3,5
4,4
5,7
Maximum electrical impendance Zmax
m
Ω
–
–
377
Rated voltage
1/N/PE ~ ... V 230
230
230
Rated current
A 15
19
25
Hot water output
∆ϑ
= 25 K
l/min 2,0
2,5
3,3
Jet regulator SR 3
•
•
–
Jet regulator SR 5
–
–
•
Flow rate „ON“
> l/min 1,6
2,0
2,6
Flow rate „OFF“
< l/min 1,1
1,4
1,7
Automatic flow regulation
l/min 2,2
2,8
4,3
Pressure drop (during switch-on flow)
MPa 0,05
0,06
0,09
Max. inlet temperature
°C 25
25
25
Protection class in accordance with
DIN EN 60335
1
1
1
Protection mode in accordance with EN 60529
IP 25
IP 25
IP 25
Test mark, see unit identification plate
•
•
•
Water connections G 3/8 (surface installation)
•
•
•
Heating system - Bare-wire
1100
Ω
cm 1) •
•
•
Area of use: low-lime and limy water
•
•
•
English
277453-34655-0750 MTH 350 - 570.15 15
14.12.2007 11:49:24
Summary of Contents for MTH 350
Page 11: ...11 Notizen Deutsch ...