A
B
3.
Place a container close to the pump
to collect any spillage.
4.
Release the emergency emptying
hose (
B
), place it in the container and
remove its cap cover.
5.
When no more water comes out, un-
screw the pump cover (
A
) by turning
it anti-clockwise and remove the fil-
ter. Use pliers, if necessary.
Always keep a rag nearby to dry up
any water spillages when removing
the cover. Clean the filter under a
tap, to remove any traces of fluff.
6.
Remove foreign bodies and fluff from
the filter seat and from the pump im-
peller.
7.
Check carefully whether the pump
impeller rotates (it rotates jerkily). If it
doesn’t rotate, please contact your
Service Centre.
ENGLISH