● If the cordset is damaged and you have to change it,
do not do the job yourselves! Take the product to an after
sales authorised repair centre or to a person with similar
skill and knowledge, in order to avoid any risk of danger.
● The appliance must be positioned so that the plug is
always accessible.
2) Positioning
● The product must be installed respecting the minimum distances from ceiling,
floor and objects at the sides indicated in picture #1.
● This infrared wall mounted heater is only suitable for mounting horizontally on
a solid vertical wall. Never install it vertically or on the ceiling as indicated in
picture #2.
● The product must not be mounted on any inflammable surface such as wood
or plastic. Any inflammable materials must be at least 100 cm. away from the
front face. This is also the minimum distance the user has to keep from the pro
-
duct because during use the front grille gets hot.
● Care should be taken to mount the appliance so that the product and the
pull cord switch are out of the reach of children. If it is installed in a bathroom, it
should be positioned so that it cannot be touched by anyone who is in the bath
or in the shower.
● After use we recommend to leave the product cool down for at least 10 – 15
minutes before touching it.
3) Installation
We recommend to switch off the mains electricity supply before proceeding
with the following steps.
● Fix the wall bracket using it as a template to drill holes for the rawplugs. Mind
that the 3 holes which hang the unit should be in the position shown in #4, NOT
upside down.
● The unit can be oriented in 2 positions.
-
Horizontally
-
Downwards
According to the orientation you prefer you have to fix the screws in position 1 if
you want the unit to be horizontal, position 2 if you want the unit to be inclined
downwards, as shown in #7.
● Remove the back plastic cover from the unit, as shown in #8.
● Remove the strain relief, as shown in #9 and feed the electric lead in from
behind through the round opening under the connection block and make con-
nections according to #9. Connect the 2 phases to the connection block. The
blue wire to the N pole, the brown wire to the L pole. L and N symbols are mar
-
ked under the connection block.
● Secure the supply powercord fixing the strain relief.
● Fix again in position the back plastic cover, as shown in #10.
● Hang the heater to the wall bracket and pull it down to securely fix it to the
bracket in the direction shown by the arrow, as in #11.
● Check that the unit is correctly fixed pulling it towards you; it shouldn’t move.
4) Connection to the mains electricity supply
● This product has a double electrical insulation protection (class II) and therefo
-
11