Depth
520 mm
9.2 Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Multi Crown
56
Semi-rapid
35
Auxiliary
28
9.3 Other technical data
TOTAL POWER:
Gas original:
G30/G31 (3B/P) 30/30 mbar 607 g/h
Gas replace‐
ment:
G20 (2H) 20 mbar
8,6 kW
Electric supply:
220-240 V ~ 50-60 Hz
Appliance cate‐
gory:
II2H3B/P
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for LPG G30/G31 30/30 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Multi Crown
3,55
1,4
095
258
Semi-rapid
1,9
0,6
71
138
Auxiliary
1,0
0,33
50
73
9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown
3,9
1,4
146
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
10. ENVIRONMENTAL CONCERNS