Auxiliary burner:
1.0 kW
TOTAL POWER:
G20(2H) 20mbar = 12 kW
G30 (3+) 28
-
30 mbar = 858 g/h
G31 (3+) 37 mbar = 843 g/h
Electric supply:
230 V ~ 50 Hz
3 core flexible cable with non rewirable plug fit-
ted with a 3 amp cartridge fuse
Category:
II2H3+
Gas connection:
G 1/2"
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By
-
pass diameters
Burner
Ø By
-
pass in 1/100 mm
Auxiliary
28
Semi
-
rapid
32
Rapid
42
Triple Crown
56
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28
-
30/37 mbar
kW
kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28–30
mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
0.33
70
0.095
50
73
71
Semi
-
rap-
id
2.0
0.45
96
0.190
71
145
143
Rapid
3.0 (natural
gas)
2.8 (LPG)
0.75
119
0.286
86
204
200
Triple
Crown
4.0
1.4
146
0.381
98
291
286