11
11
CLEANING AND CHANGING HEPA FILTER
WARNING
after each discharge cycle or if performance drops. Replace
basis.
NOTE:
Filter maintenance is important. Make sure the HEPA
completely dry before reusing in the vacuum. We recommend
in case of urgent use needed.
occur after you have checked for any obstructions in the hose
or wand. Also, install a new collection bag.
INSTALLING AND CLEANING FOAM SLEEVE FILTER
See figure 11.
1. Verify that no battery pack is inserted in the battery ports.
2. Remove power head and place in upside down position.
3. Carefully slide foam sleeve filter down over the filter cage
making sure the hole is covered.
4. Replace the power head on to the tank.
See figure 17.
1. With the removed power head in the upside down position,
carefully remove foam sleeve filter.
2. Use a mild soap and water solution to wash foam sleeve
filter and rinse with clean water.
3. Allow filter to air dry before installing and using again.
CHANGING THE DUST BAG
When the collection bag is 3/4 full, it must be replaced.
from the vacuum tank and can result in breakage and spills.
When collection bag becomes 3/4 full, turn off vacuum and
slowly remove the collection bag from the tank until the
opening in the collection bag is clear of the tank.
Use only AEG accessories and AEG spare parts. Should
components need to be replaced which have not been
described, please contact one of our AEG service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on
the label and order the drawing at your local service agents
or directly at:
Techtronic Industries (Australia) Pty. Ltd.
PO Box 1065
Mount Waverley VIC 3149
Tel. no. 1300 361 505
Australia
Techtronic Industries N.Z. Ltd
.
PO Box 12-806
Penrose AUCKLAND 1642
Tel no. 0800 279 624
New Zealand
SYMBOLS
Safety alert
Regulatory Compliance Mark (RCM). Product
meets applicable regulatory requirements.
Please read the instructions carefully before
starting the machine.
Do not dispose of electric tools together with
household waste material. Electric tools and
electronic equipment that have reached the
end of their life must be collected separately
and returned to an environmentally compatible
recycling facility.
TROUBLESHOOTING
Problem
Possible Causes
Solution
Vacuum will not operate.
1. No power supply.
2. Tank full.
1. Check if battery pack is properly inserted.
2. Check if battery pack if charged.
3. Empty tank.
Dust comes out from motor
cover.
1. The cartridge filter is missing or damaged.
2. HEPA cartridge filter is not installed
correctly.
1. Attach or replace cartridge filter.
2. Check the HEPA catridge filter and install
it correctly.
Reduced efficiency and motor/
speed vibration.
1. There is a blockage in the nozzle, hose,
or the tank inlet. The cartridge filter is
clogged by fine dust.
2. Dust bag is full.
1. Check nozzle, hose and tank inlets for
blockage. Take off the filter and clean it. Or
install a new cartridge filter.
2. Replace the dust bag.