English 21
1. Connect the red (+) terminal connection cable
with clamp (8) to the positive battery terminal.
2. Connect the black (-) terminal connection cable
with clamp (7) to the negative battery terminal.
Note:
The black (-) clamp can also be connected to the
vehicle chassis (Please refer to the auto maker‘s in-
structions!). Be sure both clamps have good contact
and are securely seated.
Warning!
Risk of fire and electric shock! If possible, connect
the charger to the 230 V power socket without
extension cable. In exceptions, use the shortest
possible undamaged and unrolled 230 V extension
cable.
3. Plug the charger plug into a 230V power socke.
the display shows the current battery voltage.
10 seconds after starting, the „Charge“ LED (10)
will light up and the charging voltage will be at the
preset lowest charging rate.
If the battery is connected incorrectly, the “Error”
LED (9) will light up. In this case, unplug the charger
and check the battery and the correct connection
(also see “Troubleshooting”).
4.
Verify the device’s preset charging voltage
(6 V or 12 V) corresponds with the connected
battery. If the charging voltage is too high, the
connected battery may be damaged/destroyed.
5.
You may repeatedly press the MODE button (12)
during charging to select the charging voltage,
charge in %, and the charging current (see „Char-
ging current“).
6.
Whilst charging you can press the tYPE button
(4) several times to select the battery type (see
„Switching Battery types“).
Note:
o charge an EFB battery please select type StD, as
this is a wet battery.
Functions
The charger is equipped with a microprocessor
(MCU - Micro Computer Unit) and features fully
automatic diagnostic, charging, and maintenance
functions. If the wrong battery voltage is set or the
battery is defective, it will not charge and the “Error”
LED (9) will light up (also see “Troubleshooting”).
The “trickle charge” function allows the charger
to be permanently connected. A full charge will be
maintained
OPERAtION
Before use
Warning!
Before using this device be sure to read the ope-
rating manual for the battery and the vehicle and
understand all safety notices.
•
Use safety goggles and acid-proof safety gloves.
•
Ensure adequate ventilation.
•
Ensure the battery poles are clean. If the battery
has removable vent caps, fill each battery cell with
distilled water to the level recommended by the
battery manufacturer. Do not overfill the cells.
•
If the battery must be removed from the vehicle
before charging, always disconnect the earthed
connector from the battery first. Also ensure all
other loads in the vehicle are off.
•
If the battery does not have caps, refer to the
manufacturer instructions on charging and the
charging speed.
Connecting the device
Charge
Full
Error
DISPLAY
SELECT
TYPE
SELECT
MODE
10 A
10 A
2 A
STD
AGM
GEL
2 A
15 A
V
A
%
BOOST
15 A
8 A
2 A
STD
AGM
GEL
2 A
15 A
V
A
%
12V/100A
6 V
12 V
V/A/%
Type
Mode