correcting the cause of an Over Temp fault condition.
Detail:This indicates that the AC mains voltage is more than +10% of nominal. The amplifier module will be forced to
Standby when an Over Voltage condition occurs. When the Over Voltage condition is cleared, the amplifier module will
automatically return to Run mode.
To clear an Over Voltage fault condition, the AC mains must be brought down to the nominal value. If the amplifiermodule
does not return to Run mode when the Over Voltage condition has cleared, the DSR 100-15 system may require
servicing.
Detail:This indicates that an Output Fault condition has occurred and the amplifier module has been placed in Standby
mode. The Fault indicator will light under two conditions: 1) High-frequency oscillation is causing high shoot-through
current; or 2) An output transistor has shorted, causing the output fault condition.