8508 OPERATOR’S MANUAL – SECTION 3
3.7 Start-up Procedure
1.
Turn down the level of your signal source.
2.
Make sure the Emergency Stop button on
the front panel is in the ON position (not
depressed).
3.
Make sure the back panel access door is
closed and the breaker switch (near the
bottom of the amplifier rear) is in the ON
position.
4.
Press the front-panel POWER switch to
turn the amplifier ON.
5.
Wait until the Run/Standby indicator turns
solid green.
6.
Adjust your input signal level to achieve
the desired output level.
Figure 3.6 – Three-Phase AC Mains Wiring