background image

17 

 

5. TROUBLE SHOOTING 

Situation 

Solution 

Fault 

Code 

Fault Event 

01 

Over charge current 

1.

 

Restart the charger. 

2.

 

If the problem remains, please contact your 

installer. 

02 

Over temperature 

1.

 

Keep the charger in the cool environment. 

2.

 

If the problem remains, please contact your 

installer. 

03 

Battery voltage under 

1.

 

Check the battery wire connection. 

2.

 

If the wire connection is ok, please contact your 

installer. 

04 

Battery voltage high 

1.

 

Reconnect the battery to the charger. 

2.

 

If the problem remains, please contact your 
installer. 

05 

PV high loss 

1.

 

Please check the voltage of the solar panel, it 

should be less than 140V.   

2.

 

If the voltage is ok, please contact your installer. 

06 

Battery  temperature 
too low 

1.

 

Check your remote temperature sensor and 

your battery ambient temperature. 

2.

 

If the problem remains, please contact your 

installer. 

07 

Battery  temperature 
too high 

1.

 

Check your remote temperature sensor and 

your battery ambient temperature. 

2.

 

If the problem remains, please contact your 

installer. 

No display in LCD screen. 

1.

 

Check battery wire connection. 

2.

 

Push the button, if the problem remains, please 
contact your installer. 

www.

ADVICE

.co.il

e-mail:advice@advice.

co.il

Summary of Contents for ASC-MPPT-3000

Page 1: ...1 Solar Charge Controller 3KW User Manual www ADVICE co il e mail advice advice co il...

Page 2: ...3 3 Mounting the Unit 6 3 4 Power Connection 7 3 5 Grounding and Ground Fault Interruption 9 3 6 Remote Temperature Sensor 9 3 7 Battery Voltage Sense 10 3 8 Communication Connections 11 4 OPERATION...

Page 3: ...reduce this risk 4 CAUTION Only qualified personnel can install this device with battery 5 NEVER charge a frozen battery 6 For optimum operation of this charger please follow required spec to select...

Page 4: ...errors or system faults occur This charger also features multifunctional LCD with communication ports for remote battery temperature and voltage measurement 2 1 Features Intelligent Maximum Power Poin...

Page 5: ...ndicator 4 Wiring fault indicator 5 Operation button 6 PV connectors 7 Battery connectors 8 Battery voltage sense terminal 9 Remote temperature sensor terminal 10 Wiring box cover 11 Communication por...

Page 6: ...oints before selecting where to install This solar charge controller is designed in IP31 for indoor applications only Do not mount the unit on flammable construction materials Mount on a solid surface...

Page 7: ...ize Typical Amperage Wire Type 75 C Wire 90 C Wire 60A Copper 4 AWG 25 mm2 6 AWG 16 mm2 Aluminum 2 AWG 35 mm2 4 AWG 25 mm2 Overcurrent Protection and Disconnects CAUTION Circuit breakers or fuses must...

Page 8: ...ches inside the charger 2 Make 4 power wires first Remove insulation sleeve 10 5mm and the conductor should be plated Tin Refer to the chart below 3 Pull all wires into the wiring box The Remote Tempe...

Page 9: ...Screw four 4 power terminals tightly with 50 in lbs torque 5 65 Nm 3 5 Grounding and Ground Fault Interruption Use a copper wire to connect the grounding terminal in the wiring box to earth ground The...

Page 10: ...connection on the controller may differ slightly from the voltage directly at the battery bank terminals due to connection and cable resistance The Battery Voltage Sense connection enables the contro...

Page 11: ...wires may be pulled through conduit with the power conductors Tighten the connector screws with 5 in lb 0 56 Nm torque The maximum length allowed for each battery voltage sense wire is 98 ft 30 m 3 8...

Page 12: ...ware CD into a computer and follow on screen instruction to install the monitoring software For the detailed software operation please check user manual of software inside of CD www ADVICE co il e mai...

Page 13: ...en it will indicate a successful start up in LCD display Turn on solar disconnect switch If the solar module is in full sunlight the controller will begin charging 4 2 Operation and Display Panel The...

Page 14: ...s it will automatically save current setting and exit the setting mode Backlight on Press shortly 4 2 LCD Display Icons Icon Function description Input Source Information Indicates the PV input voltag...

Page 15: ...de Constant Voltage mode 2V cell 4 bars will flash in turns 2 2 083V cell The right bar will be on and the other three bars will flash in turns 2 083 2 167V cell The two right bars will be on and the...

Page 16: ...g mode All current setting will be saved automatically Refer to below chart for set up charging current 4 4 Reference Code Type Code Event Fault 01 Over charge current 02 Over temperature 03 Battery v...

Page 17: ...em remains please contact your installer 05 PV high loss 1 Please check the voltage of the solar panel it should be less than 140V 2 If the voltage is ok please contact your installer 06 Battery tempe...

Page 18: ...tion 4500 Watts port Protections Solar high voltage disconnect Solar high voltage reconnect Battery high voltage disconnect Battery high voltage reconnect High temperature disconnect High temperature...

Page 19: ...tage 14 5V 29V 58V Battery defect voltage 8 5V 17V 34V Battery defect comeback voltage 9V 18V 36V Charging Curve Table 3 Mechanical and Environment Charger MODEL MPPT 3K Product size W x H x D mm 315...