Adventure Kings Generator

3. PRE-oPERAtioN ChECK

NOTE: 

pre-operation checks should be made each time the generator is 
used

1) CHECK ENGINE FUEL

•  Make sure there is sufficient fuel in the tank.

•  if fuel is low, refill with unleaded automotive gasoline.

•  be sure to use the fuel filter screen on the fuel filter neck.

•  recommended fuel: Unleaded petrol (do noT use ethanol or 

high octane fuels).

•  Fuel tank capacity:  (see page 14).

WARNING:

•  do not refill tank while engine is running or hot.

•  close fuel cock before refueling with fuel.

•  be careful not to admit dust, dirt, water or other foreign objects  

into fuel.

•  do not fill above the top of the fuel filter or it may overflow when 

the fuel heats up later and expands.

•  wipe off spilt fuel thoroughly before starting engine.

•  Keep open flames away.

2) CHECK ENGINE OIL

•  Make sure the engine oil is at the upper level of the oil filler hole. 

add oil as necessary.

•  remove oil filler cap and check the engine oil level.

•  if oil level is below the lower level line, refill with suitable oil to 

upper level line. do not screw in the oil filler cap when checking 
oil level.

•  change oil if contaminated.

•  oil capacity: (see page 14)

recommended engine oil:
SAE10 W30

3) GROUND (Earth)

•  Make sure to ground (earth) the generator. 

0°c

32°c

25°c

84°c

Summary of Contents for 2000i

Page 1: ...Petrol Inverter Generator USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE GENERATOR NOTE The generator has been shipped without engine oil Fill it with the correct oil or it will not start ...

Page 2: ...gs Generator CONTENTS 1 SAFETY INFORMATION 2 2 CONTROL FUNCTION 3 3 PRE OPERATIONCHECK 5 4 OPERATION 6 5 PERIODIC MAINTENANCE 9 6 TROUBLESHOOTING 12 7 STORAGE 13 8 SPECIFICATIONS 14 9 WIRING DIAGRAM 15 10 WARRANTY 17 ...

Page 3: ... it is kept upright If it tilts fuel may leak from the carburetor or fuel tank 3 ENGINE AND MUFFLER MAY BE HOT Place the machine in a place where pedestrians or children are not likely to touch the machine Avoid placing any flammable materials near the exhaust outlet during operation Keep the machine at least 1 m 3 ft from buildings or other equipment or the engine may overheat Avoid operating the...

Page 4: ...itch 3 Fuel tank 4 Spark plug 5 Muffler 6 Carrying handle 7 Choke lever 8 AC pilot light 9 Overload indicator light 10 Oil warning light 11 DC protector 12 12V Outlet 13 Ground earth terminal 14 AC 240V Outlet 15 AC 240V Outlet 16 Fuel filter 17 Fuel tank cap 18 Fuel pump 19 Recoil starter 20 Fuel cock 21 Oil filler cap 22 Air filter cover ...

Page 5: ... and less noise 4 DC CIRCUIT PROTECTOR The DC circuit protector turns the motor off automatically when the load exceeds the generator rated output CAUTION Reduce the load to within the specified generator rated output if the DC circuit protector turns the engine off 5 FUEL TANK CAP AIR VENT KNOB The fuel tank cap is provided with an air vent knob to stop fuel flow The air vent knob must be turned ...

Page 6: ...reful not to admit dust dirt water or other foreign objects into fuel Do not fill above the top of the fuel filter or it may overflow when the fuel heats up later and expands Wipe off spilt fuel thoroughly before starting engine Keep open flames away 2 CHECK ENGINE OIL Make sure the engine oil is at the upper level of the oil filler hole Add oil as necessary Remove oil filler cap and check the eng...

Page 7: ... using your generator for the first time of if it has been considerable time between uses press the primer bulb 6 times 5 Turn the choke lever to the CHOKE position Not necessary if the engine is warm 6 Pull the starter handle slowly until resistance is felt This is the Compression point Return the handle to its original position and pull swiftly Do not fully pull out the rope After starting allow...

Page 8: ...verter unit overheats or the AC output voltage rises The electronic breaker will then activate stopping power to the generator in order to protect the generator and any connected electric devices The output pilot light green will flicker and the overload indicator light red will turn on then the engine will stop running If so please follow these steps 4 Turn off any connected electric devices and ...

Page 9: ... battery shall be within 1 26 to 1 28 2 Connect between the DC output socket and the battery terminals using the charging leads The leads shall be connected making sure of the and polarity 3 The DC circuit protector is to be set to ON after confirming the connection if the protector is in OFF position CAUTION Be sure the economy control switch is turned OFF while charging the battery 3 STOPPING TH...

Page 10: ...Fuel Filter Clean fuel cock filter Replace if necessary Choke Check choke operation Valve Clearance Check and adjust when engine is cold Fuel Line Check fuel hose for crack or damage Replace if necessary Exhaust System Check for leakage Retighten or replace gasket if necessary Check muffler screen Clean replace if necessary Carburetor Check choke operation Cooling system Check fan damage Starting ...

Page 11: ...re no foreign material enters the crankcase Do not tilt the generator when adding engine oil This could result in overfilling and damage to the engine Clean the oil filter every other 100hr 3 AIR FILTER Maintaining an air cleaner in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Keep the element ...

Page 12: ... solvent If damaged replace 3 Wipe the filter and insert it CAUTION Be sure the tank cap is tightened securely 6 MUFFLER SCREEN CAUTION The engine and muffler will be very hot after the engine has been running Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair 1 Remove the muffler screen 2 Use the flathead screw driver ...

Page 13: ...ettor Clean carburetor 2 Engine oil system Insufficient Oil level is low Add engine oil 3 Electrical systems Poor spark Spark plug dirty with carbon or wet Remove carbon or wipe spark plug dry Faulty ignition system Consult dealer 4 Compression insufficient Worn out piston and cylinder Consult dealer 2 Generator won t produce power If Safety device AC is switched to OFF Stop the engine then restar...

Page 14: ...screw 2 ENGINE 1 Remove the spark plug pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug 2 Use the recoil starter to turn the engine over several times with ignition off 3 Pull the recoil starter until you feel compression 4 Stop pulling 5 Clean exterior of the generator and apply a rust inhibitor 6 Store the generator in a dry well ...

Page 15: ...isplacement 100 cc Max Output 2 3KW 5500rpm Fuel Unleaded petrol 91 octane no ethanol Fuel tank Capacity 4 1 liters Rated Continuous Operation 3 8 hr Lubricating oil SAE 10W30 Lubricating oil Capacity 0 75 liter Starting System Recoil Starter Ignition system C D I Spark Plug Type A5RTC TORCH DIMENSION Net dimension L W H 525 282 457 Overall dimension L W H 555 315 490 Net Weight 18 5 Kg Gross Weig...

Page 16: ... O BROWN RED WHITE ORANGE Y G YELLOW GREEN GR GRAY R R BU BU W W BL BL BL DC winding Stepping motor Control winding Economic switch PI PINK R High pressure wrap Spark plug BL W Spring winding Ignition winding R BL BR GR P Y G W O BU BU Engine switch BL BL R BL BL BL R BL Main winding FUSE 15A BREAKER 6A 12V OUTLET R O BL PI BU R O W BL BU Oil sensor ...

Page 17: ...toxicated Potential danger of explosion or fire This generator is NOT designed to be operated by persons with reduced mental and physical capabilities or children Appliances MUST be OFF before connecting to this generator NEVER START or stop this generator with extension leads appliances or loads connected ALWAYS disconnect extension leads appliances or loads before stopping this generator AVOID b...

Page 18: ...f the goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits provided to you as the consumer by this warranty are in addition to other rights and remedies available to you under the law The warranty does not cover a Any damage resulting from improper use b Faulty installation or modification made during installation c The cost of removing and reinsta...

Page 19: ...18 Adventure Kings Generator ...

Reviews: