7
Adventure Kings Generator
2) USING ELECTRIC POWER
A) AC APPLICATION
1. check the ac pilot lamp for proper voltage.
2. Turn off the switch(es) of the electrical appliance(s) before
connecting to the generator.
3. insert the plug(s) of the electrical appliance(s) into the
receptacle.
CAUTION:
• be sure the electric apparatus is turned off before plugging in.
• be sure the total load is within generator rated output.
• be sure the socket load current is within socket rated current.
• The economy control switch must be turned to “oFF” when
using electric devices that require a large starting current, such
as a compressor or a submergible pump.
B) OVERLOAD INDICATOR LIGHT
The overload indicator light comes on when an overload of a
connected electrical device is detected, the inverter unit overheats,
or the ac output voltage rises. The electronic breaker will then
activate, stopping power to the generator in order to protect the
generator and any connected electric devices. The output pilot light
(green) will flicker and the overload indicator light (red) will turn on,
then the engine will stop running. if so please follow these steps:
4. Turn off any connected electric devices and stop the engine
5. reduce the total wattage of connected electric devices within
the application range.
6. check for blockages in the cooling air inlet and around the
control unit. if any blockages are found, remove.
7. after checking, restart the engine.
CAUTION:
• The generator ac output automatically resets when the engine
is stopped and then restarted.
• The overload indicator light may come on for a few seconds
at first when using electric devices that require a large starting
current, such as a compressor or a submergible pump.
however, this is not a malfunction.
Summary of Contents for 2000i