4.3
Light Sensor Channel Configuration
Parameter
Description
Values
Default
Channel switch
Enable/disable this channel
Enable/Disable
Enable
High limit
The state becomes high if illumination
is over the high limit
0~83865, Unit: lux
550
Low limit
The state becomes low if illumination
is below low limit
0~83865, Unit: lux
450
Fast Blink
Frequency
Fast blink frequency threshold
0.2 ~ 2.55 Hz
2 Hz
mode
Light sensor state query mode
On/Off mode
On/Off/Blink mode
On/Off/
Blink mode
Delay time
In On/Off/Blink mode, if within delay
time the state keeps high/low, the
state becomes high/low
1s ~ 5s
Unit: second
2s
Filter
How many consecutive events are
required to trigger the state
(implement by sensor)
0: disable
1: 2 * conversion time Disable
Illumination
option
Whether to get illumination
0: disable
1: enable
disable
Normal state
Which state should save more power,
off or on
Off/On
off
Note!
Because of the resolution of the sensor is not always less than 1 as fol
-
lowing table, the user setting and actual light sensor setting might be
inconsistent. For example, if a user sets 83850 on high limit, FW set
83845.12 on sensor but still show 83850 to user.
Summary of Contents for WISE-S100
Page 1: ...User Manual WISE S100 ...
Page 6: ...WISE S100 Series User Manual vi ...
Page 8: ...WISE S100 Series User Manual viii ...
Page 9: ...Chapter 1 1 Product Introduction ...
Page 13: ...Chapter 2 2 Hardware Installation ...
Page 15: ...Chapter 3 3 Hardware Specification ...
Page 18: ...WISE S100 Series User Manual 10 ...
Page 19: ...Chapter 4 4 Firmware Specification ...
Page 26: ...WISE S100 Series User Manual 18 ...
Page 27: ...Appendix A A Modbus Table ...