WISE-750 supports instant data reading and input from protocols. To retrieve instant
values from WISE-750, please make sure the WISE-750 is running and then follow
the mapping table to get corresponded values.
4.8.1
Modbus
WISE-750 provides Modbus mapping for instant feature values and inspection
results. For detailed mapping table, please refer to Appendix C.
4.9
Alarm Generation
Alarm thresholds could be set in WISE-750. The setting interface is in the “Feature
Extraction” and “ML Modeling” page respectively. The inspection result could either
be retrieved from communication interfaces or corresponded digital output. For
example, if WISE-750 finds that channel 0 fail to pass the threshold, the digital output
0 will be set to High level. Otherwise, in the normal situation, the digital output will
stay in Low level. For the communication protocol table and digital output specifica
-
tion, please refer to Appendix A and Appendix C.
4.10
System Requirements
The installation package installs essential components altogether, including Python
and Tensorflow. The system should be a 64-bit Windows system, at least Windows 7
and suggested to be Windows 10.
Summary of Contents for WISE-750
Page 1: ...User Manual WISE 750 Intelligent Vibration Sensing Gateway...
Page 4: ...WISE 750 User Manual iv...
Page 10: ...WISE 750 User Manual 4...
Page 11: ...Chapter 2 2 Installation...
Page 14: ...WISE 750 User Manual 8...
Page 22: ...WISE 750 User Manual 16...
Page 34: ...WISE 750 User Manual 28...
Page 35: ...Appendix A A Specifications...
Page 38: ...WISE 750 User Manual 32...
Page 39: ...Appendix B B Algorithms...
Page 41: ...Appendix C C I O Ranges...
Page 43: ...37 WISE 750 User Manual Appendix C I O Ranges...