Page 1: ...SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page I SKY 8260S Compact 2U Carrier Grade High Performance Server based on AMD EPYC 7003 7002 Series Processors ...

Page 2: ...KY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page II Revision History Date mm dd yyyy Revision Modifications 2022 03 10 V01 First Release 2022 04 11 V02 Update Content ...

Page 3: ...is manual is organized as follows Section 1 Getting Started helps you with the first steps with the SKY 8260S Section 2 Product Specification provides a detailed description of the SKY 8260S and its features Section 3 Configuration and Service describes how to change the SKY 8260S configuration or how to install and service replaceable items Section 4 Tips Tricks and Troubleshooting provides best ...

Page 4: ... have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please ...

Page 5: ...er visibly on the outside of the package and ship it prepaid to your dealer Warnings Cautions and Notes Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are included to help you avoid damaging hardware or losing data Note Notes provide additional information We Appreciate Your Input Please let us know of any aspect of this product including the ...

Page 6: ...t and Assistance 25 Product Specification 26 2 1 Overview 27 2 2 Product Versions 28 2 3 Technical Specifications 29 2 3 1 SKY 8260S System Specification 29 2 3 2 System Dimensions 30 2 4 Detail Description 31 2 4 1 Front Elements 31 2 4 1 1 LEDs Details 32 2 4 1 2 Front Button Details 34 2 4 1 3 Fan Module Details 34 2 4 1 4 Storage LED 35 2 4 2 Rear Panel 36 2 4 2 1 Disk bay detail 37 2 4 3 Insi...

Page 7: ... 1 Jumper Settings 56 3 2 BIOS Setup Menu 56 3 3 Installing Components 77 3 3 1 Removing the Top Cover 77 3 3 2 Reinstalling the Top Cover 78 3 3 3 Middle bar installation 78 3 3 4PCIe Card Installation 78 3 3 5Disk Installation 81 3 3 5 1 2 5 HDD SSD Drives 81 3 3 5 2 M 2 SSD 82 3 3 6 Memory Installation 83 3 3 7 CPU Installation 85 3 4 Firmware Upgrades 86 3 5 Replacing FRUs 86 3 5 1 Air Filter ...

Page 8: ...___________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 8 BIOS POST Code 98 Power Supply Specification 104 C 1 Redundant 1200W AC PSU 105 C 2 Redundant 800W DC PSU 107 Declaration of Conformity 109 Warranty and RMA 111 Glossary 113 ...

Page 9: ...Figure 2 15 Location of mSATA Sockets 45 Figure 2 15 Location of internal storages 45 Figure 2 16 System Airflow and Fans 48 Figure 2 17 AC PSU Details 49 Figure 2 18 DC PSU Details 50 Figure 3 1 BIOS POST Screen 56 Figure 3 2 BIOS Setup Screen Organization 57 Figure 3 3 BIOS Setup Main Screen 57 Figure 3 4 Platform Setup Main Screen 59 Figure 3 5 Platform Setup Serial Console Menu 59 Figure 3 6 P...

Page 10: ...Figure 3 28 PCIe Card Cage Assembly Connect power cable 80 Figure 3 29 PCIe Card Cage Assembly PCIe cage guide pins 80 Figure 3 30 PCIe Card Cage Assembly External power adapter 81 Figure 3 31 Opening the Disk Tray 81 Figure 3 32 Removing the Disk Tray 82 Figure 3 33 Mounting the Drive in the Disk Tray 82 Figure 3 34 M 2 SSD Installation 83 Figure 3 35 Opening DIMM Latches 83 Figure 3 36 DIMM Key ...

Page 11: ...ils 49 Table 2 16 DC PSU Details 50 Table 2 17 Accessories 53 Table 2 18 Spare Parts 53 Table 2 19 Related Products 54 Table 3 1 Main Menu 58 Table 3 2 Serial Console Menu 60 Table 3 3 USB Configuration Menu 61 Table 3 4 Trusted Computing Menu TPM2 0 62 Table 3 5 Virtualization 63 Table 3 6 Platform Management 64 Table 3 7 CPU Configuration 66 Table 3 8 Southbridge 67 Table 3 9 SATA Configuration ...

Page 12: ...S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 12 Table A 6 RJ45 Connector LED Indication 96 Table A 7 RJ45 Management port Connector Pin Assignment 97 Table B 1 BOIS POST Codes 99 Table C 1 1200W AC Power Supply Specification 105 Table C 2 800W DC Power Supply Specification 107 ...

Page 13: ...SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 13 Chapter 1 Getting Started ...

Page 14: ...information is complete If you need additional information contact your Advantech representative The product has been designed to meet the standard industrial safety requirements It must not be used except in its specific area as specified in Section 2 3 Only personnel trained by Advantech or persons qualified in electronics or electrical engineering is authorized to install service or maintain th...

Page 15: ...ed in Technical Specifications This could damage the equipment The equipment should be in a controlled environment Caution Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer discard used batteries according to the manufacturer s instructions 16 The sound pressure level at the operator s position according to IEC 704 ...

Page 16: ...uding the protective foam using both hands Now remove the foam and the plastic sleeve on the unit After unpacking the unit please check for any visible damage of the unit and contact your Advantech representative in case of any issue Please note that unless agreed otherwise power cords need to be ordered separately Table 1 1 Packaging List Item Qty Image Description Server SKY 8260S 1 Compact 2U H...

Page 17: ...re configured system with CPUs memory and peripherals installed in the unit In the rare case that you procured a barebone system or need to install components in the SKY 8260S for any other reason please refer to Section 3 3 1 3 1 Chassis Slide Rail Installation To install the chassis slide rail on the SKY 8260S chassis please follow below instruction ...

Page 18: ...________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 18 Caution DO NOT add any weight upon the system when chassis slide rail is installed ...

Page 19: ...two VGA Ports and four USB ports for connection of a monitor keyboard and mouse Please refer to Section 2 4 for information on the location of the related connectors 1 3 4 Connecting to the Serial Console The SKY 8260S supports the operation via a serial terminal connection by default for scenarios where a directly attached monitor keyboard and mouse are not available or not desirable In this conf...

Page 20: ...___________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 20 Figure 1 1 PuTTY Session Configuration Figure 1 2 PuTTY Serial Configuration ...

Page 21: ...________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 21 Figure 1 3 PuTTY Keyboard Settings Figure 1 4 PuTTY Colour Settings ...

Page 22: ...t an OS according to the selected boot options in the BIOS In case you would extend the time the BIOS displays the POST screen and waits for a key press to enter the setup menu you can do so via the BIOS setup menu Please refer to Section 3 2 for details 1 3 5 Installing an OS Several options are available for OS installation System comes with a preinstalled OS Install an image from a USB key Inst...

Page 23: ... menu You can either give the USB stick higher boot priority over SATA devices Alternatively you can select the USB stick in the Boot Override Menu Boot Override will modify the boot order for a single boot process only and will automatically revert back to the original boot priority After making these changes leave the Setup Menu via Save Exit This will restart the server and it will boot from th...

Page 24: ...miniOS then load the actual target OS which usually consists of multiple files which decompressed and installed into a RAM disk The detailed process and required configuration of such network install will heavily depend on the target OS and boot loader miniOS used Please refer to the related documentation available PXE boot requires a DHCP server and a TFTP server in the network to complete DHCP S...

Page 25: ... Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Worldwide contact information can be found on http www advantech com 3 Please have the following information ready before you call be sure to include this information in your email Product name and serial number Description of your peripheral attachments Des...

Page 26: ...__________________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 26 Chapter 2 Product Specification ...

Page 27: ...y and faster provisioning of applications and resources are essential By pairing with multiple Network Interface Cards or Acceleration Cards e g FPGA or GPU card SKY 8260S offers a stable carrier grade service of network and computing acceleration Powered by AMD EPYC 7002 7003 processor and the highly flexible PCIE and IO expansion capability SKY 8260S can also be applied in enterprise private net...

Page 28: ...t your Advantech representative for availability of other configuration options Table 2 1 Available Product Versions Model Name Configurations Storage PSU SKY 8260SAS A0000 20 2U server with single AMD EPYC 7003 7002 Series CPU socket redundant AC 1200W PSU 4x Storages 2x 2 5 SAS SATA SSD 2x 2 5 NVMe U 2 SSD FSP AC 1200W SKY 8260SAS D0000 20 2U server with single AMD EPYC 7003 7002 Series CPU sock...

Page 29: ...EDs Rear IO 2 x GbE LAN RJ45 1 x RJ45 Management port 1 x VGA 2 x USB3 0 1 x RJ45 Console port 1 x OCP3 0 PCIe Gen4 x16 module slot Ethernet Gigabit Ethernet Interface 10 100 1000 Mbps 10 Gigabit Ethernet Interface Via OCP3 0 module Controller GbE LAN Intel i210 AT support Connector 2x RJ 45 Storage Storage Internal 2 x 2 5 SATA SSD Rear 2 x 2 5 SATA PCIe SSD Internal on board 2x M 2 2280 SATA3 PC...

Page 30: ...mpliant to IPMI2 0 with security and availability enhancements Redfish API support iKVM and Support Advantech Web GUI style Node Manager Configurable shared or dedicated NIC support Physical Dimension W x D x H 436 x 533 x 87 mm 17 19 x 20 9 x 3 48 Weight N W 18kg Security Lockable front bezel and chassis intrusion sensor NOTE 1 User can select to install two AC 1200W PSU as SKY 8260S AC system or...

Page 31: ...pyright 2022 Advantech Co Ltd All rights reserved Page 31 2 4 Detail Description 2 4 1 Front Elements Figure 2 3 Front Panel Table 2 2 Front Elements A Power button ID button LED B LCM Display optional C Bezel Security Lock D 1x USB 3 0 1X USB 2 0 ports and VGA port E Service Tag F Fan and storage status LED A D E E B C F ...

Page 32: ...n with LED Power On LED on Power off LED off A2 Blue Button with LED 1 The LEDs will be ON if the IPMI Chassis Identify command IPMIv2 0 specification Section 28 5 is received and they will be automatically OFF after 15 seconds by default 2 The LEDs will be ON if Chassis ID button on the front panel is pressed Press the button again to turn off the LEDs 3 Blinking Unit selected for identification ...

Page 33: ...stem Status LED One system status LED in red color is provided for the SKY 8260S system chassis The system status LED behavior is based on Platform Event Filtering PEF alert rules which can be configured by user The default configuration is to light up if any critical sensor threshold or critical discrete events fan failure power supply failure occurs These events will trigger the LED to light up ...

Page 34: ...s Table 2 4 Front Buttons Item Element Description A8 Power Button Power button to power up or down the unit A9 ID Button When pressed lights the ID LED A10 Reset Button Reset the system 2 4 1 3 Fan Module Details The SKY 8260S has six hot swappable fan modules at the front Each of the fan modules carries high performance fans for optimized air flow and has an integrated fan status LED to simplify...

Page 35: ...the fan module When off indicates a faulty fan module Caution DO NOT leave the slot empty when extracting the FAN module the alternative FAN module MUST be inserted immediately 2 4 1 4 Storage LED SKY 8260S contains two internal storages inside the system on the middle bar refer to 2 4 11 Internal storage The status activity LEDs of the two storages are shown in the front panel Figure 2 7 Internal...

Page 36: ... Table 2 7 Rear Panel List Item Description A Hot swappable redundant CRPS PSU B ID Button C VGA port D Console port E OCP3 0 module slot F 1 x GbE port 1x Management port G 2 x GbE ports H 2x USB2 0 3 0 ports I Up to 4x PCIe Gen 4 x16 FH FL slots Or 2x PCIe Gen 4x16 FH FL 2x PCIe Gen4 x8 FH HL slots 2x FH HL PCIe Gen 4 x8 slots J 2x PCIe x8 LP expansion slots Or 1x PCIe x16 LP expansion slot K 2x...

Page 37: ... SSDs at the rear Figure 2 9 Disk Bays Table 2 8 Disk Item Element Description K1 2 5 Disk Tray Disk 1 K2 2 5 Disk Tray Disk 2 Each Disk Bay has an integrated disk tray that includes a handle button as well as drive LEDs Figure 2 10 Disk Tray Table 2 9 Disk Tray Item Element Description K3 LED Activity LED Blue K4 LED Status LED Yellow K5 Button Pushing the button will allow the tray handle to ope...

Page 38: ...ual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 38 2 4 3 Inside the System Figure 2 11 System Top View Cover Removed Table 2 10 Internal system components list Item Element Description IS1 Intrusion Switch Switch for chassis intrusion detection CG0 0 CG1 CG2 RH1 MB1 FC1 IS1 AD1 ...

Page 39: ... RH1 Rear HDD cage 2 2 5 drive trays CG0 PCIe Card Cage PCIe Card Cage 0 For LP expansion slots CG1 PCIe Card Cage PCIe Card Cage 1 For full height expansion slots CG2 PCIe Card Cage PCIe Card Cage 2 For full height expansion slots MB1 Middle bar Carries two internal drive bays FC1 Fan Cages Cages hosting fan modules AD1 Airduct The air duct is underneath the middle bar MB1 and CG1 and CG2 ...

Page 40: ...7003 7002 series processors The table below gives an overview of the processor SKUs for communication infrastructure which can be supported on the SKY 8260S Table 2 11 AMD EPYCTM 7002 series processors supported list CPU SKU Cores Frequency Cache DDR4 TDP 7252 8 3 1GHz 64MB 3200 MHz 120W 7232P 8 3 1GHz 32MB 3200 MHz 120W 7262 8 3 2GHz 128MB 3200 MHz 155W 7F32 8 3 7GHz 128MB 3200 MHz 180W 7272 12 2...

Page 41: ...ilable from AMD 2 4 5 1 Processor Feature Details AMD EPYC processors include advanced security features that help mitigate risk Secure Encrypted Virtualization SEV to help safeguard VM privacy and integrity Secure Nested Paging SEV SNP for strong memory integrity protection capabilities Secure Memory Encryption SME to help guard against attacks on main memory AMD Shadow Stack for hardware enforce...

Page 42: ...socket D2 D4 D6 D8 D10 D12 D14 D16 DIMM 0 Black socket D1 D3 D5 D7 D9 D11 D13 D15 Table 2 13 AMD EPYCTM Processor DDR4 DIMM SMBus Address List Location CPU Channel H W Address Device Address D1 CPU1 CHA DIMM0 SA 2 0 000 A0 D2 CPU1 CHA DIMM1 SA 2 0 001 A2 D3 CPU1 CHB DIMM0 SA 2 0 010 A4 D4 CPU1 CHB DIMM1 SA 2 0 011 A6 D5 CPU1 CHC DIMM0 SA 2 0 100 A8 D6 CPU1 CHC DIMM1 SA 2 0 101 AA D7 CPU1 CHD DIMM0...

Page 43: ... the modules validated on the SKY 8260S Table 2 14 Validated DIMMs Vendor P N Capacity Speed Architecture Micron 96D4 8G3200ER MI 8G DDR4 3200 Micron 96D4 16G3200ER MI 16G DDR4 3200 Micron 96D4 32G3200ER MI 32G DDR4 3200 ATP 96D4 8G3200ER AT 8G DDR4 3200 ATP 96D4 16G3200ER AT 16G DDR4 3200 Please contact you Advantech representative for the most recent list of validated peripherals or if you would...

Page 44: ...2 4 8 PCIe Expansion The SKY 8260S has flexible SKUs for PCIe expansions PCIe cage 0 CG0 supports 2x PCIe x8 LP Gen 4 expansion slots OR 1x PCIe x16 LP Gen 4expansion slot PCIe cage 1 CG1 supports 1x FH FL PCIe x16 Gen 4 slot 1x FH FL PCIe x8 Gen4 slots 1x FH HL PCIe x8 Gen4 slots OR 2x FH FL PCIe x16 Gen 4 slots PCIe cage 1 CG2 supports 1x FH FL PCIe x16 Gen 4 slot 1x FH FL PCIe x8 Gen4 slots 1x ...

Page 45: ... supported on the SKY 8260S This module is TCG compliant and has passed Common Criteria EAL4 certification 2 4 10 Mass Storage Two M 2 2280 SSDs are supported on the SKY 8260S located at M1 underneath the air duct beside the memory slots Figure 2 15 Location of mSATA Sockets 2 4 11 Internal Storage SKY 8260S supports two internal 2 5 SSD HDD They are located on the two sides of the middle bar MB1 ...

Page 46: ...to an empty RTC battery 2 4 12 1 Password Protection The BIOS supports and administrator password to restrict access to the BIOS setup menu to qualified and trusted personal only 2 4 12 2 BIOS Defaults The BIOS comes with a set of configuration parameters when shipped by Advantech referred to as Optimized Defaults or factory defaults The user can change BIOS settings via the setup menu either temp...

Page 47: ...ists please refer to the SKY 8260S BMC User s Guide 2 4 13 1 Hardware and Environmental Monitoring BMC monitors all critical voltages on the SKY 8260S Main system voltages 12V 5V 3 3V Standby voltages 5V_SB 3 3V_SB RTC battery CPU core and IO voltages DRAM voltages Moreover the following temperatures are supervised Air inlet and outlet temperatures CPU temperatures PSU temperature via PMBus 2 4 13...

Page 48: ...through the front cover and the integrated air filter if present Six fan modules each consisting of two fans soak in the air and push it over the motherboard as well as the PCIe card cages Air outlet is through the rear side of the unit The PSU modules have integrated fans which provide for independent cooling of the PSU modules and exhaust air through the rear panel Figure 2 16 System Airflow and...

Page 49: ...lement Description PS1 Fan PSU fan and air outlet area PS2 Power Connector IEC 320 C 14 power connector PS3 Lock Lock for locking unlocking the module Pull left to unlock PS4 Status LED Green LED indicating normal operation when lit Amber LED indicating abnormal operation when lit PS5 Handle Handle for extraction insertion Caution 1 DO NOT remove the PSU before unplugging the power cable power cor...

Page 50: ...er connector PS3 Lock Lock for locking unlocking the module Pull left to unlock PS4 Status LED Green LED indicating normal operation when lit Amber LED indicating abnormal operation when lit PS5 Handle Handle for extraction insertion Caution 1 DO NOT remove the PSU before unplugging the power cable power cord 2 For 1 1 redundant system power only ONE PSU is allowed to be extracted at one time 3 DO...

Page 51: ...18 green and yellow wire of earth of building to the protective earthed terminal of the equipment 4 Connect signal cables to the product 5 Connect power cord to the product 6 Ensure correct polarity of 40 60 V dc connections 6 1 40V 60VDC is and RTN is if DC power source outputs positive voltage 6 2 40V 60VDC is and RTN is if DC power source outputs negative voltage 7 Turn ON the power source Caut...

Page 52: ...ing the top cover will activate an intrusion detection switch location IS1 Chassis intrusion will be signaled via an IPMI event by the BMC 2 5 2 Watchdogs The watchdog is implemented as an IPMI compliant watchdog timer in the BMC and supports more sophisticated operation modes such as pre timeout interrupts Standard utilities such as ipmitool can be used for configuring and strobing this watchdog ...

Page 53: ...le 2 17 Accessories Order Number Description 1700020095 Power cable 3P 180 cm USA 1702002605 Power cable 3P 180 cm Europe 1700000237 Power cable 3P 180 cm JP 1700009652 Power cord 3P 180 cm China 2 6 2 Spare Parts The following spare parts are available for ordering Table 2 18 Spare Parts Order Number Description SKY 8232D SLRLE Slide Rail set for SKY 8232D Same slide rail with SKY 8232D SKY 8232D...

Page 54: ...eserved Page 54 2 6 3 Related Products The following related products are available for ordering Table 2 19 Related Products Model Name Configurations SKY 8260SAS A0000 20 2U server with single AMD EPYC 7003 7002 Series CPU socket redundant AC 1200W PSU 4x Storage SKY 8260SAS D0000 20 2U server with single AMD EPYC 7003 7002 Series CPU socket redundant DC 800W PSU 4x Storage ...

Page 55: ...__________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 55 Chapter 3 Configuration and Service ...

Page 56: ...OS Users can modify BIOS settings and control the special features of the SKY 8260S using the BIOS setup menu Note Please note that Advantech supports shipping the SKY 8260S with custom BIOS defaults to simplify the deployment and integration for our customers Please contact your Advantech representative if you want to receive more information regarding this service The BIOS Setup Menu can be ente...

Page 57: ...le in a given menu page or a submenu thereof Auxiliary text providing information about the selected setup item is displayed in the top right corner Figure 3 2 BIOS Setup Screen Organization 3 2 1 Main Setup Menu If security protection has been enabled previously see Section 3 2 5 you will be prompted for the BIOS password upon entering the BIOS Setup After a successful check or if password protec...

Page 58: ... Language Display only Selects the Setup Menu Language Only English is supported on the SKY 8260S System Date MM DD YY Displays and sets the system date as used by the BIOS System Time HH MM SS Displays and sets the system time as used by the BIOS Access Level Display Only Shows the user privilege level according to the security settings If password protection has not been enabled this will defaul...

Page 59: ...b menu for that item Users can display an Advanced BIOS Setup option by highlighting it using the Arrow keys The Advanced BIOS Setup screen is shown below The sub menus are described on the following pages Figure 3 4 Platform Setup Main Screen 3 2 2 1 Serial Console The settings for console can be accessed in this menu This sub menu allows you to change the settings used for the serial console For...

Page 60: ...igure the number of stop bits transmitted and received in each serial character for both serial ports Parity None Even Odd Mark Space Configure if parity bit is generated transmit data or checked receive data between the last data word bit and stop bit of the serial data for both serial ports Flow Control None Hardware RTS CTS Configure flow control for console redirection Terminal Type VT100 VT10...

Page 61: ...booting to Legacy OS Default value is always Enabled which means Legacy Console Redirection is enabled for Legacy OS 3 2 2 2 USB Configuration This sub menu allows you to change the settings used for USB and to get an overview of the USB devices detected by the BIOS 4 Figure 3 6 Platform Setup USB Configuration Menu Table 3 3 USB Configuration Menu Group Setup Item Access Options Description None ...

Page 62: ... 0 Table 3 4 Trusted Computing Menu TPM2 0 Group Setup Item Access Options Description Firmware Version Display Only Display TPM firmware version Vendor Display Only Display TPM vendor Active PCR banks Display Only N A Available PCR banks Display Only N A SHA 1 PCR Bank Disabled Enabled Enable SHA 1 PCR Bank SHA256 PCR Bank Disabled Enabled Enable SHA256 PCR Bank Pending operation None TPM Clear C...

Page 63: ...ion 1 2 or 1 3 TPM 20 InterfaceType CRB TIS Show the Communication Interface to TPM 20 Device Device Select TPM 1 2 TPM 2 0 Auto Auto will support both with the default set to TPM 2 0 devices If not found TPM 1 2 devices will be enumerated TPM 2 0 HID MSFT0101 PNP0C31 Choose TPM 2 0 HID return value 3 2 2 4 Virtualization This sub menu allows you to change the settings used for Virtualization func...

Page 64: ...optimized setting for getting better performance for networking so it is not recommend to change it Figure 3 9 Platform Setup Platform Management Table 3 6 Platform Management Group Setup Item Access Options Description None Power Supply Idle Control Low Current Idle Typical Current Idle Auto Power Supply Idle Control SMT Control Disabled Enabled Auto Can be used to disable symmetric multithreadin...

Page 65: ...Y 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 65 3 2 3 Hardware Setup The sub menus are described on the following pages Figure 3 10 Hardware Setup 3 2 3 1 CPU Configuration This menu supports configuration of the AMD CPU Figure 3 11 Hardware Setup CPU Configuration ...

Page 66: ...d Page 66 Table 3 7 CPU Configuration Group Setup Item Access Options Description Node 0 CPU information CPU signature Display only Displays information on the processor installed Processor Cores CPU Frequency Processor Family Processor Model Microcode Patch L1 Cache L2 Cache L3 Cache 3 2 3 2 Northbridge 3 2 3 2 1 Socket 0 Information Figure 3 12 Hardware Setup DIMM Configuration ...

Page 67: ...ts reserved Page 67 3 2 3 3 Southbridge This menu contains settings for the South Bridge for related SATA and USB and ACPI setting etc Figure 3 13 Hardware Setup Southbridge Table 3 8 Southbridge Group Setup Item Access Options Description None SATA Configuration N A Select sub menu ACPI Settings N A Select sub menu Ac Loss Control Always Off Always On Previous No Change ...

Page 68: ...V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 68 3 2 3 3 1SATA Configuration Figure 3 14 Hardware Setup SATA Configuration Table 3 9 SATA Configuration Group Setup Item Access Options Description SATA Enable Disabled Ensabled Auto Disable or enable OnChip SATA controller 3 2 3 3 2 ACPI Settings ...

Page 69: ...Settings Table 3 10 ACPI Setting Group Setup Item Access Options Description None Enable ACPI Auto Configuration Disabled Enabled Enables or Disables BIOS ACPI Auto Configuration 3 2 3 3 3 Runtime Error Logging Figure 3 16 Hardware Setup Runtime Error Logging Table 3 11 Runtime Error Logging Group Setup Item Access Options Description None System Errors Enabled Disabled Auto System error enabling ...

Page 70: ... Advantech Co Ltd All rights reserved Page 70 3 2 3 4 NVMe Configuration This menu contains settings for NVMe controller and Drive information Figure 3 17 Hardware Setup NVMe Configuration 3 2 4 Server Management Setup The Server Mgmt menu supports configuring BMC related features such as OS Watchdog Timer etc Figure 3 18 Sever Management Setup ...

Page 71: ...oot Watchdog Timer Not available if OS Boot Watchdog Timer is disabled OS Wtd Timer Policy Do Nothing Reset Power Down Power Cycle Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled BMC Self test log Erase Log Yes On every reset No Erase Log Options When log is full Clear Log Do not log any more Select the action to be ...

Page 72: ...ord after being installed is required each time the system boots and or an attempt is made to enter the Setup program Figure 3 19 Security Menu Note 1 If set the Password Check is Setup then this only limits access to Setup and is only asked for when entering Setup 2 If set the Password Check is Always then this is a power on password and must be entered to boot or enter Setup In Setup the User wi...

Page 73: ...ion Figure 3 20 Post and Boot Menu Table 3 13 Post Boot Menu Group Setup Item Access Options Description None Setup Prompt Timeout 1 Number of seconds to wait for setup activation key Bootup NumLock State On Off Select the keyboard NumLock state Quiet Boot Disabled Enabled Enables or disables Quiet Boot option Network Stack Disabled Enabled Enables or disables boot via Network PXE UEFI PXE Support...

Page 74: ... reserved Page 74 3 2 6 2 Compatibility Support Module CSM Configuration This submenu allows users to configure the support for legacy BIOS mechanisms and option ROMs Figure 3 21 Post and Boot Menu CSM Configuration Table 3 14 CSM Configuration Group Setup Item Access Options Description None CSM Support Enabled Disabled Enables or disables the Compatibility Support Module ...

Page 75: ...se Figure 3 22 Save Exit Menu Table 3 15 Save Exit Menu Options Group Setup Item Description None Save Changes and Exit Exit setup after saving the changes Does not update User defaults Discard Changes and Exit Exit setup without saving any changes Save Changes and Reset Reset system after saving the changes Does not update User Defaults Discard Changes and Reset Reset system without saving the ch...

Page 76: ...2 Advantech Co Ltd All rights reserved Page 76 Save as User Defaults Saves the Current BIOS Settings as User Defaults Save Options Restore User Defaults Restores the User defaults to all the setup options Boot Override UEFI boot device This option allows you to override the specified boot order and use a different boot device for the next boot ...

Page 77: ... power to the unit to be shut down and removed 3 3 1 Removing the Top Cover Note You need A PH2 screwdriver The top cover is secured by two M3 screws at the side and hood latch at the top To remove the top cover loosen the screws at the side with screwdriver After that unlock the hood latch by screwdriver and press the button which will let the handle pop up Pull the handle all the way up to allow...

Page 78: ... front plate and the flange After that slide the top cover forward until the flange is fully seated underneath the face plate Press the hood latch handle back to buckle up the latch then use the screwdriver to lock the latch Finally tighten the M3 screws at the sides 3 3 3 Middle bar installation After removing the top cover please follow the steps below 1 To remove the middle bar hold the handles...

Page 79: ... The pull push direction must be with an angle of 90 from the PCIe connector You should feel a small bump when the riser card disengages with the motherboard Keep pulling the card cage to the top until it is fully removed from the chassis and put it on the desk with the riser card connector facing towards you Note For CG0 press the latch and pull the card cage at the same time Remove the PCIe cage...

Page 80: ...slot s 8 If the PCIe cards need extra power supplies connect the power cables to the PCIe card through the rear window of PCIe cage Figure 3 28 PCIe Card Cage Assembly Connect power cable 9 Turn around the card cage assembly and re insert it into the system Make sure the card cage is fully seated before you fasten the thumb screws that hold the card cage in place Note For CG0 align the two guide p...

Page 81: ...power and power on the unit 13 Enter the BIOS setup menu launch the EFI shell and use the PCIe device display command to validate that the newly installed board s has have been properly recognized 14 Leave the BIOS and boot the OS 3 3 5Disk Installation 3 3 5 1 2 5 HDD SSD Drives Note You need A PH1 screw driver A standard 2 5 HDD SSD 1 Locate the disk tray you want to install 2 Push the tray s bu...

Page 82: ...ting the Drive in the Disk Tray 5 Insert the tray into the disk bay until the drive engages with the connector on the HDD backplane Now click the handle back to the tray 3 3 5 2 M 2 SSD Note You need A PH2 screw driver A standard M 2 SSD 1 M 2 mounting screws in the accessory box 1 Remove the top cover middle bar the PCIe cage CG1 and CG2 the air duct 2 Make sure the M 2 SSD is compliant with the ...

Page 83: ...PCIe cages and air duct follow the instructions below for DIMM installation 1 Double check that the DIMMs be installed match the requirements of section 2 4 6 2 and make sure you follow the DIMM population rules given in that section 2 Open the latches on the left and right sides of the DIMMs by turning it outwards as indicated by the arrows below Figure 3 35 Opening DIMM Latches 3 Select DIMM ori...

Page 84: ... Insert the DIMM from the top using the guide rails on the left and right of the DIMM sockets Figure 3 37 DIMM Insertion into Slide Rails 5 Put your thumbs near the right and left end of the DIMM and press down the DIMM evenly until the white latches fully close with a click Figure 3 38 Seating the DIMM in the Socket 6 In case you want to install another DIMM repeat steps 1 to 5 accordingly ...

Page 85: ...ll production environment In the unlikely case that you need to install CPUs by yourself please contact your Advantech representative as product warranty may be impacted To install AMD CPU please follow the steps below 1 Loosen in 3 2 1 order 2 Lift up socket lid and carrier frame holder then remove socket protector Do not touch pins in socket 3 Slide down until processor clicks into place 4 Caref...

Page 86: ...inimized firmware component which is not subject to field updates as it does not support fail safe updates via rollback capabilities The upgrade capability of the boot loader is only intended for factory use A failing update in the field may leave the unit dysfunctional and may result in the requirement for on premise service access and or RMA For more detailed information please refer to BMC user...

Page 87: ...umb screw 3 5 2 PSU Modules Note You need no special tools A spare PSU module To replace a PSU module proceed as follows 1 Locate the PSU module to be replaced failing degraded 2 Remove the power cord from the PSU power connector 3 Grab the PSU handle and unlock the PSU module by pulling the PSU lock to the left 4 Hold the lock and extract the PSU module towards you 5 Insert a new PSU module into ...

Page 88: ...ay handle 2 Grab the tray handle and pull it evenly towards you 3 Remove the 2 5 drive mounting screws 4 Install a new HDD by following the instructions in Section 3 3 5 1 3 5 3 2 M 2 SSD Note You need A PH2 screw driver A standard M 2 SSD Power down the unit To remove a M 2 SSD proceed in the reverse of the installation procedure in section 3 3 5 2 1 Remove the top cover middle bar the PCIe card ...

Page 89: ... to remove the top cover middle bar PCIe card cages and air duct To replace a DIMM module basically extract the DIMM module by pushing the DIMM socket latches outward As the latches flip completely open the DIMM module will be automatically extracted from the socket Pull the DIMM module out vertically Figure 3 41 Unlocking and Removing a DIMM To insert a new DIMM please follow the process describe...

Page 90: ..._______________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 90 Chapter 4 Tips Tricks and Troubleshooting ...

Page 91: ...____________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 91 Appendix A Connector Pinout and LED Information ...

Page 92: ...A 1 Console Port SKY 8260S uses RJ45 connector for the console port at rear I O panel Figure A 1 RJ45 Console Connector Table A 1 Console Connector Pin Assignment Pin No Signal Name Description 1 RTS Request To Send 2 DTR Data Terminal Ready 3 TX Transmitted Data 4 GND Digital Circuit Ground 5 GND Digital Circuit Ground 6 RX Received Data 7 DSR Data Set Ready 8 CTS Clear To Send ...

Page 93: ...ont panel And one USB 2 0 connector at the front panel Figure A 2 USB Type A Connector Table A 2 USB 3 0 Type A Connector Pin Assignment or Pin Assignment Pin No Signal Name Description 1 Power USB Power 5V 900mA Fused 2 D USB 2 0 Differential Pair Signals 3 D 4 GND Digital Circuit Ground 5 SSRX USB3 0 SuperSpeed Receiver Differential Pair Signals 6 SSRX 7 GND_DRAIN Digital Circuit Ground for Sign...

Page 94: ...td All rights reserved Page 94 Table A 3 USB 2 0 Type A Connector Pin Assignment or Pin Assignment Pin No Signal Name Description 1 Power USB Power 5V 900mA Fused 2 D USB 2 0 Differential Pair Signals 3 D 4 GND Digital Circuit Ground 5 NC No connection 6 NC No connection 7 GND_DRAIN Digital Circuit Ground for Signal Return 8 NC No connection 9 NC No connection ...

Page 95: ...re two VGA ports One is located at the front panel and the other is at the rear panel Figure A 3 DisplayPort Connector Table A 4 DisplayPort Connector Pin Assignment Pin No Signal Name Description 1 Red Red video 2 Green Green video 3 Blue Blue video 4 NC No Connection 5 GND Ground 6 GND Ground 7 GND Ground 8 GND Ground 9 Power 5V DC 10 GND Ground 11 NC No Connection 12 DDC_Data I C data 13 HSYNC ...

Page 96: ...5 RJ45 10 100 1000Base T Connector Pin Assignment Pin No Signal Name Description 1 MDI 0 Media Dependent Interface 0 2 MDI 0 Media Dependent Interface 0 3 MDI 1 Media Dependent Interface 1 4 MDI 2 Media Dependent Interface 2 5 MDI 2 Media Dependent Interface 2 6 MDI 1 Media Dependent Interface 1 7 MDI 3 Media Dependent Interface 3 8 MDI 3 Media Dependent Interface 3 A 5 2 LED Definition Table A 6 ...

Page 97: ... port art ther rear I O panel Figure A 6 RJ45 management port Connector Table A 7 RJ45 Management port Connector Pin Assignment Pin No Signal Name Description 1 MDI 0 Media Dependent Interface 0 2 MDI 0 Media Dependent Interface 0 3 MDI 1 Media Dependent Interface 1 4 MDI 2 Media Dependent Interface 2 5 MDI 2 Media Dependent Interface 2 6 MDI 1 Media Dependent Interface 1 7 MDI 3 Media Dependent I...

Page 98: ..._____________________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 98 Appendix B BIOS POST Code ...

Page 99: ... 0x0F Microcode not loaded 0x10 PEI Core is started 0x11 Pre memory CPU initialization is started 0x12 Pre memory CPU initialization CPU module specific 0x13 Pre memory CPU initialization CPU module specific 0x14 Pre memory CPU initialization CPU module specific 0x15 Pre memory North Bridge initialization is started 0x16 Pre Memory North Bridge initialization North Bridge module specific 0x17 Pre ...

Page 100: ...ic 0x3E Post Memory South Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE IPL is started 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization err...

Page 101: ...idge DXE Initialization South Bridge module specific 0x75 South Bridge DXE Initialization South Bridge module specific 0x76 South Bridge DXE Initialization South Bridge module specific 0x77 South Bridge DXE Initialization South Bridge module specific 0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot ...

Page 102: ...gs 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found 0xD7 No Console Input ...

Page 103: ...ture AMI error codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery condition triggered by user Forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF5 0xF7 Reserved for future AMI progress codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB ...

Page 104: ...________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 104 Appendix C Power Supply Specification ...

Page 105: ...urrent AC line inrush current shall not exceed 35A peak for up to one quarter of the AC cycle after which the input current should be no more than the specified maximum input current The peak inrush current shall be less than the ratings of its critical components including input fuse bulk rectifiers and surge limiting device Efficiency 90 20 load 230V 94 50 load 230V 91 100 load 230V Platinum Lev...

Page 106: ...ltage Directive 2006 95 EC Europe GB4943 CBCA Certification China EMC FCC ICES 003 Emission USA Canada Verification CRISP 22 Emission International EN55032 Emission Europe EN55024 Immunity Europe EN61000 4 2 EN61000 4 3 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 2004 108 EEC Europe JEIDA Japan AS NZS CISPR 22 Au...

Page 107: ...shall be measured at an ambient temperature of 25 C after the input voltage has been removed from the power supply for a minimum of 10 minutes MTBF 1 200 000 hours at 100 load and 25 degree C excluding the Fan MTBF 2 100 000 hours at 100 load and 25 degree C Including the Fan MTBF BELL CORE TR 322 Environment Temperature Operation 0 50 C Non Operation 40 70 C Humidity Operation 5 90 RH Non Operati...

Page 108: ... CE Low Voltage Directive 2006 95 EC GB4943 CBCA Certification EMC FCC ICES 003 Emission USA Canada Verification CRISP 22 Emission International EN55022 Emission Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 2004 108 EEC Europe JEIDA Japan AS NZS CISPR 22 Australia New Zealand GB 9254 2008 EMC Certification China GB 17625 1 Harmonic...

Page 109: ..._________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 109 Appendix D Declaration of Conformity ...

Page 110: ...ed for external wiring FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not ...

Page 111: ..._____________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 111 Appendix E Warranty and RMA ...

Page 112: ...eriod For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered for example Advantech products used other hardware and software used etc Note anything abnormal and list any o...

Page 113: ...________________________________________________________________________________________ SKY 8260S Manual V02 20220411 Copyright 2022 Advantech Co Ltd All rights reserved Page 113 Appendix F Glossary ...

Page 114: ...MC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface LOM Lights Out Management MAC Media Access Control MTBF Mean Time Between Failures NIC Network Interface Controller NMC Network Mezzanine Card NVRAM Non volatile Random Access Memory OOS Out Of Service PCH Platform Controllers Hub PCIe PCI Express PECI Platform Environment Control Interface PCI SIG PCI Spe...

Page 115: ... Ltd All rights reserved Page 115 SATA Serial Advanced Technology Attachment SCSI Small Computer System Interface SDR Sensor Data Record SerDes Serializer Deserializer SOL Serial Over LAN SSD Solid State Disk SW Software TPM Trusted Platform Module TX Transmit UDIMM Unbuffered DIMM UHCI Universal Host Controller Interface USB Universal Serial Bus ...

Page 116: ...ifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permission of the publisher All brand and product names are trademarks or registered trademarks of their respective ...

Reviews: