Chapter 2 Hardware Installation 13
Standard Mode
In this mode, each of the four ports has been set up as an address, as
shown below.
Port 1
Ch1
base address
3F8
Port 2
Ch2
base address
2F8
Port 3
Ch3
base address
3E8
Port 4
Ch4
base address
2E8
Enhanced Mode
In this mode, each of the four ports has been set up as an address
individually. Select an address which is not already in use by another
card in the system. If you are installing more than one PCL-849 card
in your system, set the cards to different base adresses. DIP switches
control each card's base address, as shown below.
Port base address (S1)
Base Address
A
3
A
4
A
5
A
6
A
7
A
8
200-21F
l
l
l
l
l
l
208-227
¡
l
l
l
l
l
· · · · · · · · · ·
2E8-307
¡
l
¡
¡
¡
l
· · · · · · · · · ·
*300-31F
l
l
l
l
l
¡
· · · · · · · · · ·
3E0-3FF
l
l
¡
¡
¡
¡
l
: on
¡
: off