47
Chapter 4
4.3.2 Operation Mode Select Command
Manual mode.
Operation initiated in the start mode continues until the
stop command is transferred.
Origin return mode.
Operation initiated in the start mode continues until
the mechanical origin signal or stop command comes.
Preset mode.
Operation initiated in the start mode, stops when the quan-
tity set for register R0 is reached.
Operation in the high speed start mode ramps down when the remaining
quantity of the counter is less than the quantity set for register R5.
0 (+) direction
1 (-) direction
PCI-1243U supports two acceleration/deceleration modes. You can
choose linear accel/decal mode by setting bit5 as ‘0’. On the other hand,
if bit6 is set to ‘1’, then the acdel/decal profile will be S-curve.
0
1
0
0
*
0
0
0
0
1
0
0
*
0
0
1
0
1
0
0
*
1
0
0
0
1
*
0
0
0
0
0
0
1
0
7
6
5
4
3
2
1
0
1: ORG signal enable
1: SD+ signal enable
0: (+)direction
1: (-)direction
Operation Mode Select Command
1: Preset enable
Accel/decal characteristic
:
0
:
Linear
1
:
S-curve