45
MIC-3392 User Manual
Chapter 3
IPMI
3.4
BMC Reset
The BMC can initiate a graceful shutdown of the MIC-3392 by issuing a short pulse
(~500 ms) on the power button signal to the ACPI controller when commanded
through its host, OOB, or IPMB channels as well as from a Graceful Shutdown Event
from the CMM or a Handle OPEN event. An ACPI compliant OS will then perform a
graceful shutdown and light the blue LED whereas a non-compliant OS will just shut
down.
Note!
The Network function (NetFn) field identifies the functional class of the
message. The Network Function clusters IPMI commands into different
sets. Please refer to the IPMI specification of network function codes for
more information.
These command codes are compliant with the IPMI specification.
Mandatory and Optional commands are defined in the IPMI specifica-
tion. For more details, please refer to the IPMI specification.
Summary of Contents for MIC-3392
Page 8: ...MIC 3392 User Manual viii...
Page 13: ...Chapter 1 1 Hardware Configuration This chapter describes how to configure MIC 3392 hardware...
Page 30: ...MIC 3392 User Manual 18...
Page 31: ...Chapter 2 2 AMI BIOS Setup This chapter describes how to configure the AMI BIOS...
Page 49: ...Chapter 3 3 IPMI This chapter describes IPMI con figuration...
Page 58: ...MIC 3392 User Manual 46...
Page 59: ...Appendix A A Pin Assignments This appendix describes pin assignments...
Page 69: ...Appendix C C CPLD This appendix describes CPLD configuration...