Chapter 2: Hardware setup
2-36
2. Remove all the fans and unscrew the fan rack.
3. Unplug the cables connected to the mid-fan board.
4. Remove rack fan for the power supply first and then loosen the screw that
fastens the fan rack to the power supply cage.
5. Carefully lift the fan rack upward to remove it from the chassis.
6. Unscrew the mid-fan board and remove it from the fan rack.
7. Unscerw the main fan boards and remove them from the chassis.