FWA-2112 User Manual
24
Before run the utility, you must configure lbpcu.cfg, which is in the same directory
with lbpcu utility, with correct information of the LAN ports.
This lbpcu.cfg can be created by manual or by following section8.1 utility ndi(please
refer to ndi usermanual).
Following is a sample of lbpcu.cfg.
Following is a sample of run this utility.
-GMSM: Get the mode status of segment.
-SML: Set the duty and the period of master LED in bypass or disconnect.
-GML: Get the duty and the period of master LED in bypass or disconnect.
-CUI: [Upgrade] Check upgrade image
-UG: [Upgrade] Upgrade FW
-GFM: [Upgrade] Get FW mode
-CBTEST:evnet change callback test
-i: Get all settings of one segment
-CheckFW: check FW and fix eeprom settings if error in eeprom detected.
NOTE: if the command needs input <segment>, then you could use "a" to tell lbpcu
runs this command on all segments.
-SMSM command doesn't support this feature.
example: ./lbpcu -GW a
#cat lbpcu.cfg
SEGMENT: 1
BUS: 6
DEV: 0
FUN: 0
SEGMENT: 2
BUS: 8
DEV: 0
FUN: 0
TYPE: PCIE
# sudo ./lbpcu -VF a
================================================
Seg 1 :
Firmware version: 01.22
================================================
Seg 2 :
Firmware version: 01.22
================================================
# sudo ./lbpcu -LoadDefault a COPPER